Site Preparation and Planning
Before you install the IBM System Storage DR550 we recommend that you consider several things
to avoid problems during the installation and configuration. The DR550 comes as an almost ready to
use system with a complete assembled hardware in a rack (or two) and preconfigured software.
Nevertheless we review some topics of importance when planning for the physical installation and
configuration of the IBM System Storage DR550 within your environment.
Planning to be done is centered on integrating the rack(s) into the operational IT environment. The
racks themselves are already assembled. To integrate the rack(s) into your environment you have to
plan or validate the following:
•
The size of the floor area required by the DR550 rack(s)
– Floor load capacity
– Space needed for expansion
– Service clearance
– Check for potential clearance problems along the access route
•
The power requirements
– Multiple 208 volt or 220 volt 30 amp (single phase) power service feeds
2 feeds for 5.6, 11.2 and 22.4 TB configurations (both dual engine and single
engine configurations)
4 feeds for 89.6 TB configurations
– Each feed of a pair are recommended to be on a different AC power feed for
increased availability
– Power cords are shipped with each rack
•
Climate control is required (Environmental Class A)
•
Cables and Connectors
– RJ-45 to 9-pin converter cable to administer from the front serial port of pSeries
(included) – this is an option that only offers limited functions
•
The network environment
– IP addresses
– Check for address conflicts before cabling to your network
The table below shows selected factory IP address settings and provides a column to enter the IP
addresses to be used later when configuring the DR550. Other IP addresses within DR550 do not
need to be changed.
Dual Node Configuration
IP Description
IP Address from Factory
IP Address in Network
drs_engine1_boot
192.168.1.21
drs_engine1_stdby
192.168.2.10
drs_engine2_boot
192.168.1.23
drs_engine2_stdby
192.168.2.11
drs_cluster_svc
192.168.1.22
Single Node Configuration
IP Description
IP Address from Factory
IP Address in Network
drs_engine
192.168.1.11
Refer to
Configuring the System (P5 520 Servers)
section for additional information on IP
addresses used for the DR550.