on the switch. These cables would also need to be connected to the customer network. You can
then access the switch using the IP address. The Userid is
ADMIN
and the password is
PASSWORD. You should change this password to confirm with site security guidelines.
If you should need to review the configuration or zoning within the switches, the IP address for
switch 1 is 192.168.1.31 and switch 2 (only installed in dual node configurations) is 192.168.1.32.
These addresses should not be changed. To gain access to the switches via the IP network, you
will need to provide Ethernet cables and ports on your existing Ethernet network. Once the
connections have been made, then you can connect to the IP address and use the management
tools provided by the switch.
Dual Node Zoning – without Enhanced Remote Volume Mirroring
2005-B16_1
1
0
2
3
4
5
6
2
3
7
Engine2
Engine1
Slot 5
Slot 4
2005-B16_2
Zone 1
Zone 2
Zone 3
Slot 1
1
0
2
3
4
5
6
2
3
7
Zone 1
Zone 2
Zone 3
Note: Zone 3 is configured for use with the tape (TS1120, TS3310, 358x, 3592 with WORM