v
Alarms
connector:
The
LAN
module
provides
one
telco
DB15
alarms
connector
(male)
for
critical,
major,
and
minor
telco
alarms.
Each
of
the
alarms
has
a
relay
that
enables
multiple
system
alarm
indicators
to
be
daisy-chained
together.
shows
the
pinouts
for
the
telco
alarms
connector.
Alarms
1
8
9
15
Note:
The
service
processor,
management
module,
or
systems-management
function
must
monitor
the
alarm
reset
inputs
to
maintain
the
fault
condition
that
you
set
for
the
unit.
The
alarm
reset
inputs
can
be
voltages
in
excess
of
standard
logic
levels,
so
you
must
to
electrically
or
optically
isolate
them
from
the
monitoring
logic.
Table
1.
Telco
alarms
connector
pinout
Pin
#
Description
I/O
Pin
#
Description
I/O
1
Minor
alarm
reset
+
I
9
Minor
alarm
normally
closed
O
2
Minor
alarm
reset
-
I
10
Minor
alarm
common
O
3
Major
alarm
reset
+
I
11
Major
alarm
normally
open
O
4
Major
alarm
reset
-
I
12
Major
alarm
normally
closed
O
5
Critical
alarm
normally
open
O
13
Major
alarm
common
O
6
Critical
alarm
normally
closed
O
14
Reserved
7
Critical
alarm
common
O
15
Reserved
8
Minor
alarm
normally
open
O
The
electrical
specifications
for
the
alarms
connector
are
as
follows:
–
Outputs
-
Voltage
range:
0
V
dc
to
-100
V
dc
(maximum
current
0.3
A
at
100
V
dc)
-
Current
range:
0
A
to
1
A
(maximum
voltage
30
V
dc
at
1
A)
-
Worst-case
VA:
1
A
at
-30
V
dc
(30
VA
maximum)
indefinitely
–
Inputs
-
Voltage
range:
0
V
dc
to
-100
V
dc
(including
transients)
-
Differential
input
voltage:
3
V
dc
to
72
V
dc
–
Reset
input
activation
Pulse
width:
200
ms
(minimum)
to
300
ms
26
BladeCenter
T
Management
Module:
Installation
Guide
Summary of Contents for BladeCenter T Series
Page 1: ...BladeCenter T Management Module Installation Guide...
Page 2: ......
Page 3: ...BladeCenter T Management Module Installation Guide...
Page 20: ...6 BladeCenter T Management Module Installation Guide...
Page 34: ...20 BladeCenter T Management Module Installation Guide...
Page 42: ...28 BladeCenter T Management Module Installation Guide...
Page 66: ...52 BladeCenter T Management Module Installation Guide...
Page 73: ...Japanese Voluntary Control Council for Interference VCCI statement Appendix C Notices 59...
Page 74: ...60 BladeCenter T Management Module Installation Guide...
Page 78: ...64 BladeCenter T Management Module Installation Guide...
Page 79: ......
Page 80: ...Part Number 13N0323 Printed in USA 1P P N 13N0323...