Removing the blade server from the BladeCenter unit

The following illustration shows how to remove the blade server from the
BladeCenter unit.

Attention:

v

To maintain proper system cooling, do not operate the BladeCenter unit for more
than one minute without either a blade server, expansion unit, or filler blade
installed in each blade bay.

v

Note the bay number. Reinstalling a blade server into a different bay than the
one from which it was removed could have unintended consequences. Some
configuration information and update options are established according to bay
number; if you reinstall the blade server into a different bay, you might need to
reconfigure the blade server.

Complete the following steps to remove the blade server:

1. If the blade server is operating, shut down the operating system; then, press the

power-control button (behind the blade server control panel door) to turn off the
blade server. See “Blade server controls and LEDs” on page 15 for more
information about the location of the power-control button.

Attention:

Wait at least 30 seconds, until the drives stop spinning, before

proceeding to the next step.

2. Open the two release levers as shown in the illustration. The blade server

moves out of the bay approximately 0.6 cm (0.25 inch).

3. Pull the blade server out of the bay. Spring-loaded doors further back in the bay

move into place to cover the bay temporarily.

4. Place either a filler blade or another blade server in the bay within one minute.

The recessed spring-loaded doors will move out of the way as you insert the
blade server or filler blade.

20

BladeCenter HS20 Type 8832: Installation and User’s Guide

Summary of Contents for BladeCanter HS20

Page 1: ...on Guide and User s Installation and User s Guide Install and start the blade servers Install addtional applications such as IBM systems management software and IBM ServeRAID programs System is ready...

Page 2: ...r loose connections and verify that all optional devices you installed are on the ServerProven list You can view the ServerProven list at http www ibm com pc compat Server working properly Problem sol...

Page 3: ...BladeCenter HS20 Type 8832 Installation and User s Guide ERserver...

Page 4: ...endix B Warranty information on page 67 and Appendix C Notices on page 79 First Edition July 2003 Copyright International Business Machines Corporation 2003 All rights reserved US Government Users Res...

Page 5: ...embly 22 Installing IDE hard disk drives 22 Installing memory modules 24 Installing an additional microprocessor 25 Installing an I O expansion card 29 Installing a SCSI storage expansion unit 31 Inst...

Page 6: ...and information from the World Wide Web 65 Software service and support 66 Hardware service and support 66 Appendix B Warranty information 67 Warranty period 67 Problem determination 67 Running diagno...

Page 7: ...Japanese Voluntary Control Council for Interference VCCI statement 83 Index 85 Contents v...

Page 8: ...vi BladeCenter HS20 Type 8832 Installation and User s Guide...

Page 9: ...lleert eerst de veiligheidsvoorschriften Ennen kuin asennat t m n tuotteen lue turvaohjeet kohdasta Safety Information Avant d installer ce produit lisez les consignes de s curit Vor der Installation...

Page 10: ...ect signal cables v Never turn on any equipment when there is evidence of fire water or structural damage v Disconnect the attached power cords telecommunications systems networks and modems before yo...

Page 11: ...products such as CD ROMs DVD drives fiber optic devices or transmitters are installed note the following v Do not remove the covers Removing the covers of the laser product could result in exposure to...

Page 12: ...he device and the power switch on the power supply do not turn off the electrical current supplied to the device The device also might have more than one power cord To remove all electrical current fr...

Page 13: ...act a service technician Statement 13 DANGER Overloading a branch circuit is potentially a fire hazard and a shock hazard under certain conditions To avoid these hazards ensure that your system electr...

Page 14: ...xii BladeCenter HS20 Type 8832 Installation and User s Guide...

Page 15: ...ical updates 1 Go to http www ibm com pc support 2 In the Learn section click Online publications 3 On the Online publications page in the Brand field select Servers 4 In the Family field select Blade...

Page 16: ..._____________ The machine type model number and serial number are on the ID label that is behind the control panel door on the front of the blade server and on a label on the right side of the blade s...

Page 17: ...hatever identifying information you want on a label and place it on the BladeCenter bezel just below the blade server as shown in the following illustration User label Important Do not place the label...

Page 18: ...s Guide This publication contains instructions for setting up and configuring the BladeCenter unit and basic instructions for installing some options It also contains general information about the Bla...

Page 19: ...two Ultra320 SCSI hot swap hard disk drives available in an optional SCSI storage expansion unit Size v Height 24 5 cm 9 7 inches v Depth 44 6 cm 17 6 inches v Width 2 9 cm 1 14 inches v Maximum weigh...

Page 20: ...X Architecture technology leverages proven innovative IBM technologies to build powerful scalable reliable Intel processor based servers Enterprise X Architecture technology includes features such as...

Page 21: ...of the RAS features that your blade server supports v Advanced Configuration and Power Interface ACPI v Automatic error retry or recovery v Automatic server restart v Built in monitoring for temperat...

Page 22: ...to remove the blade server from the BladeCenter unit and remove the blade server cover to see the components Note The illustrations in this document might differ slightly from your hardware Bezel asse...

Page 23: ...J13 IDE connector 2 J62 I O expansion option connector J34 I O expansion option connector J9 Control panel connector J64 Microprocessor socket 2 and heat sink filler U70 Microprocessor 1 and heat sin...

Page 24: ...r is removed from the BladeCenter unit by pressing the Light Path Diagnostics button The Light Path Diagnostics power present LED CR111 lights when the Light Path Diagnostics button is pressed if powe...

Page 25: ...is turned on and starts the Configuration Setup Utility program so that you can change or delete the power on password You do not need to move the switch back to the default position after the passwo...

Page 26: ...12 BladeCenter HS20 Type 8832 Installation and User s Guide...

Page 27: ...rocessor in the BladeCenter management module is initializing therefore the power control button on the blade server does not respond 2 While the blade server is powering up the power on LED on the fr...

Page 28: ...ou can press the power control button on the blade server behind the control panel door This starts an orderly shutdown of the operating system if this feature is supported by your operating system No...

Page 29: ...ing system in this blade server to recognize the CD ROM drive diskette drive and USB port If there is no response when you press the CD diskette USB select button you can use the management module Web...

Page 30: ...video and mouse control to the blade server If there is no response when you press the keyboard mouse video select button you can use the management module Web interface to see if local control has be...

Page 31: ...server v Running the Broadcom firmware CD for a blade server 3 If you install Microsoft Windows 2000 on the blade server while it is not the current owner of the keyboard video and mouse a delay of u...

Page 32: ...18 BladeCenter HS20 Type 8832 Installation and User s Guide...

Page 33: ...ssor and heat sink Handling static sensitive devices Attention Static electricity can damage electronic devices and your system To avoid damage keep static sensitive devices in their static protective...

Page 34: ...e the blade server 1 If the blade server is operating shut down the operating system then press the power control button behind the blade server control panel door to turn off the blade server See Bla...

Page 35: ...lines on page 19 2 Carefully lay the blade server down on a flat non conductive surface with the cover side up 3 Press the blade cover release on each side of the blade server and lift the cover open...

Page 36: ...inch 4 Disconnect the control panel cable from the control panel connector 5 Pull the bezel assembly away from the blade server 6 Store the bezel assembly in a safe place Installing IDE hard disk driv...

Page 37: ...he option kit into an IDE connector on the blade server system board Important Drives must be installed in the following order IDE connector 1 J13 first then IDE connector 2 J62 6 Place the hard disk...

Page 38: ...same size speed type and technology You can mix compatible DIMMs from various manufacturers 5 The second pair does not have to be DIMMs of the same size speed type and technology as the first pair 6...

Page 39: ...surface on any other grounded rack component Then remove the DIMM from the package 7 To install the DIMMs repeat the following steps for each DIMM that you install a Turn the DIMM so that the DIMM key...

Page 40: ...determine whether you need to update the blade server BIOS code The latest level of BIOS code for your blade server is available from the World Wide Web See Appendix A Getting help and technical assi...

Page 41: ...assembly see Removing the blade server bezel assembly on page 22 for instructions 6 Locate the microprocessor socket on the system board 7 Remove the heat sink filler 8 Install the microprocessor a Re...

Page 42: ...roprocessor over the microprocessor socket Align the triangle on the corner of the microprocessor with the triangle on the corner of the socket and carefully press the microprocessor into the socket A...

Page 43: ...and 4 on the BladeCenter unit must both be compatible with the Ethernet expansion card All other I O expansion cards installed on other blade servers in the BladeCenter unit must also be compatible wi...

Page 44: ...secured the tray to the system board otherwise remove the screws near IDE connector 2 that secure the system board to the chassis as shown in the illustration 6 Install the I O expansion card a Insta...

Page 45: ...orage capacities and speeds of the drives are identical Notes 1 After you install the SCSI storage expansion unit on your blade server the blade server and expansion unit become a single unit that occ...

Page 46: ...n is in blade bays 7 through 14 power modules must be present in power bays 1 and 2 and power modules must be present in power bays 3 and 4 8 Turn on the blade server 9 If you have not already done so...

Page 47: ...at hard disk drive is faulty and must be replaced Each hot swap hard disk drive that you plan to install must be mounted in a hot swap drive tray The hard disk drive must have a Single Connector Attac...

Page 48: ...assembly into the bay until it stops d Push the tray handle to the closed locked position e Check the hard disk drive LEDs to verify that the hard disk drive is operating properly v If the amber hard...

Page 49: ...wap hard disk drive or a filler panel installed in each storage expansion unit bay 1 Review the information in Safety beginning on page vii and Installation guidelines on page 19 2 Locate the defectiv...

Page 50: ...ou must reconfigure your blade server and reset the system date and time Statement 2 CAUTION When replacing the lithium battery use only IBM Part Number 33F8354 or an equivalent type battery recommend...

Page 51: ...t easier to slide the battery b Use your thumb and index finger to pull the battery from under the battery clip Note After you remove the battery ensure that the battery clip is touching the base of t...

Page 52: ...e blade server cover unless you installed the SCSI storage expansion unit option see Closing the blade server cover on page 40 Statement 21 CAUTION Hazardous energy is present when the blade server is...

Page 53: ...nel cable Complete the following steps to install the blade server bezel assembly 1 Review the information in Safety beginning on page vii and Installation guidelines on page 19 2 Connect the control...

Page 54: ...vii and Installation guidelines on page 19 2 If you removed the blade bezel assembly replace it now See Installing the blade server bezel assembly on page 39 for instructions 3 Lower the cover so tha...

Page 55: ...1 and 2 and power modules must be present in power bays 3 and 4 c To help ensure proper cooling performance and system reliability make sure that each of the blade bays on the front of the BladeCenter...

Page 56: ...reconfigure the blade server If this is the initial installation for a blade server in the BladeCenter unit you need to configure the blade server with the blade server Configuration Setup Utility an...

Page 57: ...rmation Input output connectors and devices The input output connectors available to your blade server are supplied by the BladeCenter unit See the documentation that comes with your BladeCenter unit...

Page 58: ...44 BladeCenter HS20 Type 8832 Installation and User s Guide...

Page 59: ...remote management such as with the IBM Director products see the IBM Eserver BladeCenter Planning and Installation Guide You can obtain the planning guide from the Web site at http www ibm com pc eser...

Page 60: ...he service processor each time the blade server is started Use the number keys to type the hours and minutes and or to add or subtract from the system time If you want the system clock time to be the...

Page 61: ...croprocessor cache mode to write back WB or write through WT Write back caching generally provides better system performance PCI Bus Control Select this choice to view and set interrupts for PCI devic...

Page 62: ...the blade server is turned on You can then start the Configuration Setup Utility program and change the power on password You do not need to move the switch back to the previous position after the pas...

Page 63: ...t index html Firmware updates IBM will periodically make firmware updates available for your blade server Use the following table to determine the methods you can use to install these firmware updates...

Page 64: ...will vary based on blade server type and the operating system that is installed See Blade server Ethernet controller enumeration on page 51 for information about how to determine the routing from Ethe...

Page 65: ...s thru module in switch module bay 1 2 Make sure the ports on the switch module or pass thru module are enabled Switch Tasks Management Advanced Switch Management in the management module Web based us...

Page 66: ...52 BladeCenter HS20 Type 8832 Installation and User s Guide...

Page 67: ...tion with these devices 2 Some operating systems such as Red Hat Linux 7 3 permit you to select the type of mouse being used If offered this choice select USB instead of PS 2 Although the mouse is a P...

Page 68: ...54 BladeCenter HS20 Type 8832 Installation and User s Guide...

Page 69: ...8 for more information v Diagnostic programs and error messages The system diagnostic programs are provided in ROM These programs test the major components of your blade server The IBM Director produc...

Page 70: ...f the blade server then restart the blade server If the problem remains call for service POST error messages The following table provides an abbreviated list of the error messages that might appear du...

Page 71: ...Configuration Setup Utility program and verify that the interrupt resource settings are correct 2400 2462 Video controller and memory v Verify that the keyboard mouse video select button LED on the fr...

Page 72: ...oblem persists see the IBM BladeCenter Type 8677 Hardware Maintenance Manual and Troubleshooting Guide on the IBM BladeCenter Documentation CD The screen is blank Verify that 1 The keyboard mouse vide...

Page 73: ...marketing representative If the problem remains call for service Wrong characters appear on the screen If the wrong language is displayed update the firmware or operating system with the correct lang...

Page 74: ...e server If the blade server now turns on troubleshoot the option see the documentation that comes with the option for information 3 Try another blade server in the blade bay if it works replace the f...

Page 75: ...ormation about obtaining ServerProven compatibility information from the World Wide Web v You followed the installation instructions that came with the option v The option is installed correctly v You...

Page 76: ...using the Light Path Diagnostics problems that might arise during installation To locate the actual component that caused the error you must locate the lit error LED on that component For example A bl...

Page 77: ...s power present LED does not light when the Light Path Diagnostics button is pressed no power is available to light the blade error LEDs and they will be unable to provide any diagnostic information D...

Page 78: ...the fan 2 Make sure the room temperature is not too high See Features and specifications on page 5 for temperature information If the problem remains have the blade server serviced System board error...

Page 79: ...information that contains troubleshooting procedures and explanations of error messages and error codes If you suspect a software problem see the information for the operating system or program Using...

Page 80: ...ww ibm com planetwide for support telephone numbers In the U S and Canada call 1 800 IBM SERV 1 800 426 7378 Hardware service and support You can receive hardware service through IBM Integrated Techno...

Page 81: ...sed in the Statement of Limited Warranty Frequently Asked Questions FAQ and links to Product Support Web pages The IBM Statement of Limited Warranty is available from this Web site in 29 languages in...

Page 82: ...e that apply to your hardware v Customer replaceable units CRUs Some parts of IBM Eserver systems are designated as customer replaceable units IBM ships CRUs to you for replacement by you CRUs include...

Page 83: ...estrictions that apply at the time of service To determine whether your system is eligible for IWS go to http www ibm com pc support and click Warranty lookup Purchasing additional services During and...

Page 84: ...e it with one that is at least functionally equivalent you may return it to your place of purchase and your money will be refunded Extent of Warranty The warranty does not cover the repair or exchange...

Page 85: ...involve the removal of parts and their return to IBM A part that replaces a removed part will assume the warranty service status of the removed part Before IBM or your reseller exchanges a Machine or...

Page 86: ...RISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU Governing Law Both you and IBM consent to the appl...

Page 87: ...on which shall be held in Singapore in accordance with the rules of the International Chamber of Commerce ICC The arbitrator or arbitrators designated in conformity with those rules shall have the pow...

Page 88: ...urposes of a business as defined in that Act Limitation of Liability The following is added to this Section Where Machines are not acquired for the purposes of a business as defined in the Consumer Gu...

Page 89: ...costs for Machines located outside 50 kilometers of an IBM authorized service provider Governing Law The applicable laws that govern interpret and enforce rights duties and obligations of each of us a...

Page 90: ...l be at IBM s expense Limitation of Liability The following paragraph is added to this Section The limitations and exclusions specified in the Statement of Limited Warranty will not apply to damages c...

Page 91: ...nt to or in any way related to the subject matter of this Statement of Warranty IBM s liability will be limited to the total amount you paid for the Machine that is the subject of the claim Applicabil...

Page 92: ...2 of the Supply of Goods and Services Act 1982 Applicability of suppliers and resellers unchanged The following is added to the end of this Section IBM s entire liability and your sole remedy whether...

Page 93: ...F ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Some states do not allow disclaimer of...

Page 94: ...countries or both Microsoft Windows and Windows NT are trademarks of Microsoft Corporation in the United States other countries or both UNIX is a registered trademark of The Open Group in the United S...

Page 95: ...ials must be removed and recycled or discarded according to applicable regulations IBM offers product return programs in several countries For country specific instructions refer to the following Web...

Page 96: ...nada Australia and New Zealand Class A statement Attention This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take...

Page 97: ...Taiwanese Class A warning statement Chinese Class A warning statement Japanese Voluntary Control Council for Interference VCCI statement Appendix C Notices 83...

Page 98: ...84 BladeCenter HS20 Type 8832 Installation and User s Guide...

Page 99: ...oller enumeration 51 cover closing 40 removing 21 D diagnostic tools 55 DIMM See memory module drive hot swap installing 33 35 internal installing 22 E electrical input 5 electronic emission Class A n...

Page 100: ...n self test continued error messages 56 power problem 59 60 power on password 48 Preboot eXecution Environment PXE option 46 disabling 46 enabling 46 problems hardware 55 memory 60 microprocessor 61 m...

Page 101: ...blade server 14 turning on the blade server 13 U United States electronic emission Class A notice 81 United States FCC Class A notice 81 updating firmware 49 utility Configuration Setup Utility progra...

Page 102: ...88 BladeCenter HS20 Type 8832 Installation and User s Guide...

Page 103: ......

Page 104: ...Part Number 59P6556 Printed in U S A 1P P N 59P6556...