b.
Locate
the
SMP
Expansion
cable
that
is
connected
to
port
2
on
node
3;
then,
connect
the
opposite
end
of
the
cable
to
port
2
of
node
6.
Next,
route
the
cable
through
the
node
6
cable-management
arm.
c.
Locate
the
SMP
Expansion
cable
that
is
connected
to
port
3
on
node
5;
then,
connect
the
opposite
end
of
the
cable
to
port
3
of
node
6.
Next,
route
the
cable
through
the
node
6
cable-management
arm.
9.
Connect
the
SMP
Expansion
cables
to
node
7:
a.
Locate
the
SMP
Expansion
cable
that
is
connected
to
port
1
on
node
6;
then,
connect
the
opposite
end
of
the
cable
to
port
1
of
node
7.
Next,
route
the
cable
through
the
node
7
cable-management
arm.
b.
Locate
the
SMP
Expansion
cable
that
is
connected
to
port
2
on
node
2;
then,
connect
the
opposite
end
of
the
cable
to
port
2
of
node
7.
Next,
route
the
cable
through
the
node
7
cable-management
arm.
c.
Connect
one
end
of
an
SMP
Expansion
cable
to
port
3
on
node
7;
then,
route
the
cable
through
the
node
7
cable-management
arm.
Use
a
2.3-m
(7.6-foot)
SMP
Expansion
cable
for
this
connection.
10.
Connect
the
SMP
Expansion
cables
to
node
8:
a.
Locate
the
SMP
Expansion
cable
that
is
connected
to
port
1
on
node
5;
then,
connect
the
opposite
end
of
the
cable
to
port
1
of
node
8.
Next,
route
the
cable
through
the
node
8
cable-management
arm.
b.
Locate
the
SMP
Expansion
cable
that
is
connected
to
port
2
on
node
4;
then,
connect
the
opposite
end
of
the
cable
to
port
2
of
node
8.
Next,
route
the
cable
through
the
node
8
cable-management
arm.
c.
Locate
the
SMP
Expansion
cable
that
is
connected
to
port
3
on
node
7;
then,
connect
the
opposite
end
of
the
cable
to
port
3
of
node
8.
Next,
route
the
cable
through
the
node
8
cable-management
arm.
11.
Route
any
remaining
cables
through
the
cable-management
arms.
12.
Secure
the
cables
in
the
cable-management
arms
with
the
hook-and-loop
straps
that
come
with
the
server.
13.
Configure
the
scalable
partition.
See
“Using
the
Scalable
Partition
Web
Interface”
on
page
51.
Chapter
2.
Installing
options
29
Summary of Contents for 88728AU - System x3950 - 8872 Datacenter High Availability
Page 3: ...IBM System x3950 Type 8872 and System x3950 E Type 8874 Installation Guide...
Page 42: ...30 IBM System x3950 Type 8872 and System x3950 E Type 8874 Installation Guide...
Page 68: ...56 IBM System x3950 Type 8872 and System x3950 E Type 8874 Installation Guide...
Page 104: ...92 IBM System x3950 Type 8872 and System x3950 E Type 8874 Installation Guide...
Page 105: ......