v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
Chapter
3,
“Parts
listing,
Type
8863,”
on
page
93
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only)”,
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
215-xxx-000
Failed
CD
or
DVD
test.
1.
Run
the
test
again
with
a
different
CD
or
DVD.
2.
Reseat
the
following
components:
a.
CD
or
DVD
drive
b.
Front
panel
assembly
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
CD
or
DVD
drive
b.
(Trained
service
technician
only)
Front
panel
assembly
217-xxx-000
Failed
BIOS
fixed
disk
test.
Note:
If
RAID
is
configured,
the
fixed
disk
number
refers
to
the
RAID
logical
array.
Reseat
and,
if
necessary,
replace
hard
disk
drive
1.
217-xxx-001
Failed
BIOS
fixed
disk
test.
Note:
If
RAID
is
configured,
the
fixed
disk
number
refers
to
the
RAID
logical
array.
Reseat
and,
if
necessary,
replace
hard
disk
drive
2.
217-xxx-002
Failed
BIOS
fixed
disk
test.
Note:
If
RAID
is
configured,
the
fixed
disk
number
refers
to
the
RAID
logical
array.
Reseat
and,
if
necessary,
replace
hard
disk
drive
3.
217-xxx-003
Failed
BIOS
fixed
disk
test.
Note:
If
RAID
is
configured,
the
fixed
disk
number
refers
to
the
RAID
logical
array.
Reseat
and,
if
necessary,
replace
hard
disk
drive
4.
217-xxx-004
Failed
BIOS
fixed
disk
test.
Note:
If
RAID
is
configured,
the
fixed
disk
number
refers
to
the
RAID
logical
array.
Reseat
and,
if
necessary,
replace
hard
disk
drive
5.
217-xxx-005
Failed
BIOS
fixed
disk
test.
Note:
If
RAID
is
configured,
the
fixed
disk
number
refers
to
the
RAID
logical
array.
Reseat
and,
if
necessary,
replace
hard
disk
drive
6.
217-198-xxx
Could
not
establish
drive
parameters.
1.
Check
the
drive
cables
and
terminators.
2.
Reseat
and,
if
necessary,
replace
the
hard
disk
drive.
301-xxx-000
Failed
keyboard
test.
Note:
After
installing
a
USB
keyboard,
you
might
have
to
use
the
Configuration/Setup
Utility
program
to
enable
keyboardless
operation
and
prevent
the
POST
error
message
301
from
being
displayed
during
startup.
1.
Reseat
the
following
components:
a.
Keyboard
b.
I/O
board
2.
Replace
the
components
listed
in
step
1
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
302-xxx-xxx
Failed
mouse
test.
1.
Reseat
the
following
components:
a.
Mouse
b.
I/O
board
2.
Replace
the
components
listed
in
step
1
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
Chapter
2.
Diagnostics
75
Summary of Contents for 8863 - eServer xSeries 366
Page 1: ...IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 8: ...vi IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 28: ...12 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 114: ...98 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 148: ...132 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 158: ...142 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 169: ...V video connector 6 VRM LED 52 W Web site 1 weight 3 World Wide Web 1 Index 153...
Page 170: ...154 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 171: ......
Page 172: ...Part Number 31R1508 Printed in USA 1P P N 31R1508...