![IBM 8863 - eServer xSeries 366 Service Manual Download Page 83](http://html1.mh-extra.com/html/ibm/8863-eserver-xseries-366/8863-eserver-xseries-366_service-manual_4278811083.webp)
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
Chapter
3,
“Parts
listing,
Type
8863,”
on
page
93
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only)”,
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
089-xxx-0nn
Failed
microprocessor
test,
where
nn=APIC
ID.
APIC
ID
(physical
mode)
Microprocessor
00,
01,
02,
03
1
04,
05,
06,
07
2
10,
11,
12,
13
3
14,
15,
16,
17
4
APIC
ID
(logical
mode)
Microprocessor
00,
01,
02,
03
1
24,
25,
26,
27
2
10,
11,
12,
13
3
34,
35,
36,
37
4
1.
Reseat
the
following
components:
a.
(Trained
service
technician
only)
Microprocessor
nn
b.
Microprocessor
tray
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
a.
(Trained
service
technician
only)
Microprocessor
nn
b.
(Trained
service
technician
only)
Microprocessor
tray
155-xxx-xxx
Failed
Active
Memory
™
latch
test.
Note:
Make
sure
you
re-enable
the
memory
in
the
Configuration/Setup
Utility
program.
See,
“Memory
problems”
on
page
40
1.
Reseat
the
memory
card.
2.
Replace
the
memory
card.
166-051-000
System
Management:
Failed.
Unable
to
communicate
with
ASM.
It
may
be
busy.
Run
the
test
again.
1.
Update
the
firmware
(BIOS,
service
processor,
and
diagnostics;
see
“Updating
the
firmware”
on
page
133).
2.
Run
the
diagnostic
test
again.
3.
Correct
other
error
conditions
(including
failed
systems-management
tests
and
items
that
are
logged
in
the
Remote
Supervisor
Adapter
II
SlimLine
system-error
log)
and
retry.
4.
Disconnect
all
server
and
option
power
cords
from
the
server,
wait
30
seconds,
reconnect
the
power
cords,
and
retry.
5.
Reseat
the
Remote
Supervisor
Adapter
II
SlimLine.
6.
Replace
the
Remote
Supervisor
Adapter
II
SlimLine.
Chapter
2.
Diagnostics
67
Summary of Contents for 8863 - eServer xSeries 366
Page 1: ...IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 8: ...vi IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 28: ...12 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 114: ...98 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 148: ...132 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 158: ...142 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 169: ...V video connector 6 VRM LED 52 W Web site 1 weight 3 World Wide Web 1 Index 153...
Page 170: ...154 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 171: ......
Page 172: ...Part Number 31R1508 Printed in USA 1P P N 31R1508...