Error
code
Description
Action
166-060-000
System
Management:
Failed.
Unable
to
communicate
with
ASM.
It
may
be
busy.
Run
the
test
again.
1.
Update
the
firmware
(BIOS,
service
processor,
and
diagnostics;
see
“Updating
the
firmware”
on
page
133).
2.
Run
the
diagnostic
test
again.
3.
Correct
other
error
conditions
(including
failed
systems-management
tests
and
items
that
are
logged
in
the
Remote
Supervisor
Adapter
II
SlimLine
system-error
log)
and
retry.
4.
Disconnect
all
server
and
option
power
cords
from
the
server,
wait
30
seconds,
reconnect
the
power
cords,
and
retry.
5.
Reseat
the
Remote
Supervisor
Adapter
II
SlimLine.
6.
Replace
the
Remote
Supervisor
Adapter
II
SlimLine.
166-070-000
System
Management:
Failed.
Unable
to
communicate
with
ASM.
It
may
be
busy.
Run
the
test
again.
1.
Update
the
firmware
(BIOS,
service
processor,
and
diagnostics;
see
“Updating
the
firmware”
on
page
133).
2.
Run
the
diagnostic
test
again.
3.
Correct
other
error
conditions
(including
failed
systems-management
tests
and
items
that
are
logged
in
the
Remote
Supervisor
Adapter
II
SlimLine
system-error
log)
and
retry.
4.
Disconnect
all
server
and
option
power
cords
from
the
server,
wait
30
seconds,
reconnect
the
power
cords,
and
retry.
5.
Reseat
the
Remote
Supervisor
Adapter
II
SlimLine.
6.
Replace
the
Remote
Supervisor
Adapter
II
SlimLine.
166-198-000
BIOS
cannot
detect
ASM.
Reseat
ASM
adapter
in
correct
slot;
ASM
restart
failure.
Unplug
and
cold
boot
server
to
reset
ASM.
1.
Run
the
diagnostic
test
again.
2.
Correct
other
error
conditions
(including
other
failed
systems-management
tests
and
items
that
are
logged
in
the
Remote
Supervisor
Adapter
II
SlimLine
system-error
log)
and
retry.
3.
Disconnect
all
server
and
option
power
cords
from
the
server,
wait
30
seconds,
reconnect
the
power
cords,
and
retry.
4.
Reseat
the
following
components:
a.
Remote
Supervisor
Adapter
II
SlimLine
b.
I/O
board
5.
Replace
the
components
listed
in
step
4
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
166-201-000
ISMP
indicates
I2C
errors
on
bus
X.
Reseat
and,
if
necessary,
replace
the
I/O
board.
68
IBM
xSeries
366
Type
8863:
Problem
Determination
and
Service
Guide
Summary of Contents for 8863 - eServer xSeries 366
Page 1: ...IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 8: ...vi IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 28: ...12 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 114: ...98 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 148: ...132 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 158: ...142 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 169: ...V video connector 6 VRM LED 52 W Web site 1 weight 3 World Wide Web 1 Index 153...
Page 170: ...154 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 171: ......
Page 172: ...Part Number 31R1508 Printed in USA 1P P N 31R1508...