POST
beep
codes
A
beep
code
is
a
combination
of
short
or
long
beeps
or
a
series
of
short
beeps
separated
by
pauses.
For
example,
a
“1-2-3”
beep
code
is
one
beep,
a
pause,
two
beeps,
a
pause,
and
three
beeps.
When
POST
is
completed,
one
beep
is
emitted
to
indicate
that
the
server
is
working
correctly.
If
POST
detects
a
problem
during
startup,
other
beep
codes
might
occur.
See
“Beep
code
descriptions”
to
help
diagnose
and
solve
problems
that
are
detected
during
startup.
If
no
beep
code
sounds,
see
“No-beep
symptoms”
on
page
18.
Beep
code
descriptions
The
following
table
describes
the
beep
codes
and
suggested
actions
to
correct
the
detected
problems.
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
Chapter
3,
“Parts
listing,
Type
8863,”
on
page
93
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only)”,
that
step
must
be
performed
only
by
a
trained
service
technician.
Beep
code
Description
Action
1-1-3
CMOS
write/read
test
failed.
1.
Reseat
the
following
components:
a.
Battery
b.
I/O
board
2.
Replace
the
components
listed
in
step
1
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
1-1-4
BIOS
ROM
checksum
failed.
1.
Reseat
the
microprocessor
tray.
2.
(Trained
service
technician
only)
Replace
the
microprocessor
tray.
1-2-1
Programmable
interval
timer
failed.
1.
Reseat
the
I/O
board.
2.
Replace
the
I/O
board.
1-2-2
DMA
initialization
failed.
1.
Reseat
the
I/O
board.
2.
Replace
the
I/O
board.
1-2-3
DMA
page
register
write/read
failed.
1.
Reseat
the
I/O
board.
2.
Replace
the
I/O
board.
1-2-4
RAM
refresh
verification
failed.
1.
Reseat
the
following
components:
a.
DIMM
b.
Memory
card
2.
Replace
the
components
listed
in
step
1
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
1-3-1
1st
64K
RAM
test
failed.
1.
Reseat
the
following
components:
a.
DIMM
b.
Memory
card
2.
Replace
the
components
listed
in
step
1
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
14
IBM
xSeries
366
Type
8863:
Problem
Determination
and
Service
Guide
Summary of Contents for 8863 - eServer xSeries 366
Page 1: ...IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 8: ...vi IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 28: ...12 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 114: ...98 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 148: ...132 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 158: ...142 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 169: ...V video connector 6 VRM LED 52 W Web site 1 weight 3 World Wide Web 1 Index 153...
Page 170: ...154 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 171: ......
Page 172: ...Part Number 31R1508 Printed in USA 1P P N 31R1508...