Insertion Loss
Insertion loss is a measure of signal power loss due to the connecting hardware and is
derived from swept frequency voltage measurements on short lengths of Type 1A
twisted pair test leads before and after splicing-in the connector under test. The
insertion loss of any pair within a connector must not exceed the values listed in the
following table.
Table 30 shows the maximum insertion loss for the 150-ohm STP Data Connector
(applies to Prime and Self-Shorting paths):
Data Grade Media (DGM)
Plenum (P), non-plenum (NP), riser (R), and non-plenum office (NPO): all indoor
cables except under-carpet require 65% (minimum) braid-over aluminum shielding.
The shielding percentage is calculated per MIL-C-915E. Aluminum-backed insulating
tape is wrapped around the two pairs. (Individual or S-shaped aluminum shielding
must be used around Type 1 and Type 2 DGM pairs and is optional for Type 6 and
Type 9 DGM pairs.) A tinned-copper braided shield envelopes these shielded pairs to
complete the DGM core. The aluminum must make contact with the braided shield
continuously along the entire cable length.
Under-carpet (UC) Shield
The under-carpet cable has a copper foil wrapped around each pair individually. The
seam of each copper foil must face the center of the cable.
Table 30. Maximum Insertion Loss for the 150-ohm STP Data Connector
Frequency dB
100 kHz
0.05
1 MHz
0.05
4 MHz
0.05
8 MHz
0.1
10 MHz
0.1
16 MHz
0.15
20 MHz
0.15
25 MHz
0.15
31.25 MHz
0.15
62.50 MHz
0.2
100 MHz
0.25
300 MHz
0.45
Summary of Contents for 8265
Page 1: ...8265 Nways ATM Switch Planning and Site Preparation Guide GA33 0460 0 IBM...
Page 2: ......
Page 3: ...8265 Nways ATM Switch Planning and Site Preparation Guide GA33 0460 01 IBM...
Page 8: ...vi IBM 8265 Planning and Site Preparation Guide...
Page 10: ...viii IBM 8265 Planning and Site Preparation Guide...
Page 14: ...xii IBM 8265 Planning and Site Preparation Guide...
Page 16: ...xiv IBM 8265 Planning and Site Preparation Guide...
Page 26: ...10 IBM 8265 Planning and Site Preparation Guide...
Page 38: ...22 IBM 8265 Planning and Site Preparation Guide...
Page 70: ...54 IBM 8265 Planning and Site Preparation Guide...
Page 118: ...102 IBM 8265 Planning and Site Preparation Guide...
Page 121: ...Copyright IBM Corp 1994 1998 105 Appendix C Blank Planning Charts...
Page 122: ...106 IBM 8265 Planning and Site Preparation Guide...
Page 123: ...Appendix C Blank Planning Charts 107...
Page 124: ...108 IBM 8265 Planning and Site Preparation Guide...
Page 126: ...110 IBM 8265 Planning and Site Preparation Guide...
Page 128: ...112 IBM 8265 Planning and Site Preparation Guide...
Page 130: ...114 IBM 8265 Planning and Site Preparation Guide...
Page 132: ...116 IBM 8265 Planning and Site Preparation Guide...
Page 134: ...118 IBM 8265 Planning and Site Preparation Guide...
Page 136: ...120 IBM 8265 Planning and Site Preparation Guide...
Page 138: ...122 IBM 8265 Planning and Site Preparation Guide...
Page 140: ...124 IBM 8265 Planning and Site Preparation Guide...
Page 142: ...126 IBM 8265 Planning and Site Preparation Guide...
Page 144: ...128 IBM 8265 Planning and Site Preparation Guide...
Page 146: ...130 IBM 8265 Planning and Site Preparation Guide...
Page 148: ...132 IBM 8265 Planning and Site Preparation Guide...
Page 152: ...136 IBM 8265 Planning and Site Preparation Guide...
Page 163: ......