Removing a drive from the 7063-CR2 system
To remove a drive from the IBM Power Systems HMC (7063-CR2) system, complete the steps in this
procedure.
Procedure
1. Attach the electrostatic discharge (ESD) wrist strap.
The ESD wrist strap must be connected to an unpainted metal surface until the service procedure is
completed, and if applicable, until the service access cover is replaced.
Attention:
• Attach an electrostatic discharge (ESD) wrist strap to the front ESD jack, to the rear ESD jack,
or to an unpainted metal surface of your hardware to prevent the electrostatic discharge from
damaging your hardware.
• When you use an ESD wrist strap, follow all electrical safety procedures. An ESD wrist strap
is used for static control. It does not increase or decrease your risk of receiving electric shock
when using or working on electrical equipment.
• If you do not have an ESD wrist strap, just prior to removing the product from ESD packaging
and installing or replacing hardware, touch an unpainted metal surface of the system for a
minimum of 5 seconds. If at any point in this service process you move away from the system,
it is important to again discharge yourself by touching an unpainted metal surface for at least
5 seconds before you continue with the service process.
2. Remove the drive. Use the position information indicated by the service log.
a) Push in the left side of the handle release latch (A) to unlock the drive bay handle (B).
b) Pull out the drive bay handle (B) toward you. If the drive bay handle is not all the way out, the drive
cannot slide out of the system.
c) Support the bottom of the drive as you slide it out of the system. Do not hold the drive by the
handle.
d) Place the drive on an ESD surface.
Figure 9. Removing a drive
Removing and replacing parts in the 7063-CR2 11