Figure 6. Connecting the control panel cable
3. Install the service access cover.
For instructions, see “Installing the service access cover on a 7063-CR2 system” on page 105.
4. Replace the system in the rack and replace the components that you removed.
For instructions, see “Placing a 7063-CR2 system into the operating position” on page 103.
5. Power on the system for operation.
For instructions, see “Starting the 7063-CR2 system ” on page 98.
Removing and replacing the USB cable in the 7063-CR2
Learn how to remove and replace the USB cable in the IBM Power Systems HMC (7063-CR2) system.
Removing the USB cable from the 7063-CR2 system
To remove the USB cable from the IBM Power Systems HMC (7063-CR2) system, complete the steps in
this procedure.
Procedure
1. Attach the electrostatic discharge (ESD) wrist strap.
The ESD wrist strap must be connected to an unpainted metal surface until the service procedure is
completed, and if applicable, until the service access cover is replaced.
Attention:
• Attach an electrostatic discharge (ESD) wrist strap to the front ESD jack, to the rear ESD jack,
or to an unpainted metal surface of your hardware to prevent the electrostatic discharge from
damaging your hardware.
• When you use an ESD wrist strap, follow all electrical safety procedures. An ESD wrist strap
is used for static control. It does not increase or decrease your risk of receiving electric shock
when using or working on electrical equipment.
• If you do not have an ESD wrist strap, just prior to removing the product from ESD packaging
and installing or replacing hardware, touch an unpainted metal surface of the system for a
minimum of 5 seconds. If at any point in this service process you move away from the system,
it is important to again discharge yourself by touching an unpainted metal surface for at least
5 seconds before you continue with the service process.
2. Power off the system.
For instructions, see “Stopping the 7063-CR2 system” on page 99.
3. Place the system in the service position on an ESD surface on a table.
For instructions, see “Placing a 7063-CR2 system into the service position” on page 101.
4. Remove the service access cover.
For instructions, see “Removing the service access cover from a 7063-CR2 system” on page 104.
5. Remove the USB cable.
a) Label where the USB cable (A) connects to the power distribution board and to the control panel.
Removing and replacing parts in the 7063-CR2 9