• Quorum node
• GUI server
• Call home server
• Deployment container
The protocol server has the following roles:
• SMB/NFS protocols supported
• Deployed from the EMSVM container
• IBM Storage Scale/protocol functionality setup by the IBM Storage Scale toolkit
• Minimum of two nodes required
Note: For IBM Elastic Storage System , the utility node supports only the single-socket configuration.
Table 3. Specifications for a dual-socket utility node
System
Form factor
2U rackmount
Chassis model
MTM 5149 - 23E
Chassis dimension (D x W x H)
25 in. x 17.26 in. x 3.43 in. (640 x
438.4 x 87 mm)
Processor socket type
2 x SP3 LGA4094
Gross weight
25 kg (55 lb)
Net weight
16 kg (35.2 lb)
Front panel
Buttons
• One reset button
• One ID button
• One power button with LED
LEDs
• Two SSD
• Two LAN
• One ID
• One BMC event
I/O ports
• Two USB 3.1 Gen 1 ports (for
service use only)
System cooling configuration
FAN
Six 6 cm fans
Power supply
Type
CRPS
Input range
AC 100 - 127 V/12 A, AC 200 -
240 V/9.48 A
Frequency
50 - 60 Hz
Output Watts
1200 W (optional 1300 W/2000
W)
Efficiency
80 Plus Platinum (optional
Titanium)
Redundancy
1 + 1
Chapter 2. Technical overview 21
Summary of Contents for 6.1.8.2
Page 8: ...viii...
Page 20: ...xx IBM Storage Scale System Utility Node Hardware Planning and Installation Guide...
Page 90: ...70 IBM Storage Scale System Utility Node Hardware Planning and Installation Guide...
Page 96: ...76 IBM Storage Scale System Utility Node Hardware Planning and Installation Guide...
Page 100: ...80 IBM Storage Scale System Utility Node Hardware Planning and Installation Guide...
Page 102: ...82 IBM Storage Scale System Utility Node Hardware Planning and Installation Guide...
Page 110: ...90 IBM Storage Scale System Utility Node Hardware Planning and Installation Guide...
Page 112: ...92 IBM Storage Scale System Utility Node Hardware Planning and Installation Guide...
Page 113: ......
Page 114: ...IBM Product Number 5765 DME 5765 DAE SC28 3469 00...