The
select
button
and
navigation
buttons
help
you
to
navigate
and
select
menu
and
boot
options,
and
start
a
service
panel
test.
The
select
button
is
located
on
the
front
panel
of
the
SAN
Volume
Controller,
near
the
navigation
buttons.
Front
panel
display
The
front
panel
display
shows
service,
configuration,
and
navigation
information.
Information
on
the
front
panel
display
is
available
in
several
languages.
The
display
can
show
both
alphanumeric
information
and
graphical
information
(progress
bars).
The
front
panel
displays
configuration
and
service
information
about
the
SAN
Volume
Controller
and
the
SAN
Volume
Controller
cluster,
including
the
following
items:
v
Boot
progress
indicator
v
Boot
failed
v
Charging
v
Hardware
boot
v
Node
rescue
request
v
Power
failure
v
Powering
off
v
Recovering
v
Restarting
v
Shutting
down
v
Error
codes
Node
identification
label
The
node
identification
label
on
the
front
panel
displays
a
six-digit
node
identification
number.
The
node
identification
label
is
the
same
as
the
six-digit
number
that
is
used
in
the
svctask
addnode
command.
It
is
readable
by
system
software
and
is
used
by
configuration
and
service
software
as
a
node
identifier.
The
node
identifier
can
also
be
displayed
on
the
front
panel
display
when
node
is
selected
from
the
menu.
If
the
service
controller
assembly
front
panel
is
replaced,
the
configuration
and
service
software
displays
the
number
that
is
printed
on
the
front
of
the
replacement
panel.
Future
error
reports
contain
the
new
number.
No
cluster
reconfiguration
is
necessary
when
the
front
panel
is
replaced.
SAN
Volume
Controller
2145-4F2
rear
panel
indicators
The
following
figure
shows
the
rear
panel
indicators
on
the
SAN
Volume
Controller
2145-4F2
back
panel
assembly.
Appendix
B.
SAN
Volume
Controller
2145-4F2
105
Summary of Contents for 2145UPS-1U
Page 2: ......
Page 8: ...vi IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 56: ...18 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 72: ...34 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 102: ...64 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 138: ...100 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 190: ...152 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 192: ...154 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 200: ...162 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 228: ...190 IBM System Storage SAN Volume Controller Hardware Installation Guide...
Page 231: ......
Page 232: ...Part Number 31P1046 Printed in USA GC27 2132 01 1P P N 31P1046...