Environment
Environment
Temperature
Altitude
Relative
humidity
Maximum
wet
bulb
temperature
Operating
in
lower
altitudes
10°C
to
35°C
(50°F
to
95°F)
0
to
914
m
(0
to
2998
ft.)
8%
to
80%
noncondensing
23°C
(74°F)
Operating
in
higher
altitudes
10°C
to
32°C
(50°F
to
88°F)
914
to
2133
m
(2998
to
6988
ft.)
8%
to
80%
noncondensing
23°C
(74°F)
Powered
off
10°C
to
43°C
(50°F
to
110°F)
-
8%
to
80%
noncondensing
27°C
(81°F)
Storing
1°C
to
60°C
(34°F
to
140°F)
0
to
2133
m
(0
to
6988
ft.)
5%
to
80%
noncondensing
29°C
(84°F)
Shipping
-20°C
to
60°C
(-4°F
to
140°F)
0
to
10668
m
(0
to
34991
ft.)
5%
to
100%
condensing,
but
no
precipitation
29°C
(84°F)
Heat
output
The
heat
output
(maximum)
is
350
watts
(1195
Btu
per
hour).
Related
reference
Ensure
that
your
physical
site
meets
the
installation
requirements
for
the
uninterruptible
power
supply
(UPS).
Fibre-channel
port
numbers
and
worldwide
port
numbers
Fibre-channel
ports
are
identified
by
their
physical
port
number
and
by
a
worldwide
port
number
(WWPN).
The
physical
port
numbers
identify
fibre-channel
cards
and
cable
connections
when
you
perform
service
tasks.
The
WWPNs
are
used
for
tasks
such
as
fibre-channel
switch
configuration
and
to
uniquely
identify
the
devices
on
the
SAN.
provides
a
view
of
the
rear
of
the
SAN
Volume
Controller
2145-8F4.
The
physical
port
numbers
are
1
-
4,
counting
from
left
to
right
when
you
view
the
rear
panel
of
the
SAN
Volume
Controller
2145-8F4.
The
WWPNs
are
derived
from
the
worldwide
node
number
(WWNN)
of
the
SAN
Volume
Controller
in
which
the
card
is
installed.
svc00177
1
2
3
4
Figure
18.
The
port
numbers
for
the
SAN
Volume
Controller
2145-8F4
Chapter
1.
SAN
Volume
Controller
overview
25
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
||
|
|
|
||
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Summary of Contents for 2145-4F2
Page 1: ...IBM System Storage SAN Volume Controller Installation Guide V ersion 4 1 0 GC26 7900 00...
Page 2: ......
Page 3: ...IBM System Storage SAN Volume Controller Installation Guide V ersion 4 1 0 GC26 7900 00...
Page 8: ...vi IBM System Storage SAN Volume Controller Installation Guide...
Page 74: ...44 IBM System Storage SAN Volume Controller Installation Guide...
Page 78: ...48 IBM System Storage SAN Volume Controller Installation Guide...
Page 120: ...90 IBM System Storage SAN Volume Controller Installation Guide...
Page 122: ...92 IBM System Storage SAN Volume Controller Installation Guide...
Page 128: ...98 IBM System Storage SAN Volume Controller Installation Guide...
Page 134: ...104 IBM System Storage SAN Volume Controller Installation Guide...
Page 138: ...108 IBM System Storage SAN Volume Controller Installation Guide...
Page 141: ......
Page 142: ...Part Number 31P0797 Printed in USA GC26 7900 00 1P P N 31P0797...
Page 143: ...Spine information IBM System Storage SAN Volume Controller Installation Guide Version 4 1 0...