Thermal
The table shows the specifications for the thermal sensors.
Table 15. Thermal specifications
Specification
Quantity
Thermal sensors
2 per sideplane (2 sideplanes per drawer)
2 per drawer baseplane (front)
1 per drawer baseplane (middle/rear)
2 per power supply
Number in SBB I/O module is dependent on module type
Airflow with all fans running
120 liters/second maximum
Temperature and humidity
The table shows the temperature and humidity limits for the enclosure.
Table 16. Temperature and humidity limits
Factor
Operating
Non-operating
Temperature range
41°F (5°C) to 95°F (35°C)
-40°F (-40°C) to 158°F (70°C)
Relative humidity
20%rh to 80%rh non-condensing 5%rh to 100%rh non-condensing
Maximum wet bulb
82°F (28°C)
84°F (29°C)
Cooling modules
Each of the five cooling modules contains 2 stacked fans: 80mm x 80mm x 38mm.
SBB I/O module
A separate specification exists for each SBB I/O module.
Power supply unit (PSU)
The table shows the specifications of the PSU.
Table 17. PSU specifications
Category
Value
Output power
2814W maximum continuous output power at high
line voltage
Voltage
+12V at 233A (2796W total output power)
+5V standby voltage at 2.7A
Input voltage range
200 to 240VAC
Input frequency
50 to 60Hz
Power factor correction
>0.95 @ 100% load
50 IBM ESS expansion: Installation and User Guide - Model 084
Summary of Contents for 084
Page 1: ...IBM ESS expansion Version 5 3 5 Installation and User Guide Model 084 IBM SC27462802...
Page 8: ...viii...
Page 14: ...xiv IBM ESS expansion Installation and User Guide Model 084...
Page 22: ...8 IBM ESS expansion Installation and User Guide Model 084...
Page 32: ...18 IBM ESS expansion Installation and User Guide Model 084...
Page 38: ...24 IBM ESS expansion Installation and User Guide Model 084...
Page 42: ...28 IBM ESS expansion Installation and User Guide Model 084...
Page 62: ...48 IBM ESS expansion Installation and User Guide Model 084...
Page 66: ...52 IBM ESS expansion Installation and User Guide Model 084...
Page 77: ......
Page 78: ...IBM SC27462802...