Figure 36. Removing a Cooling Module (2)
Important: The cooling module bay must not be empty for more than two minutes while the enclosure is
powered up.
Inserting a cooling module
1. Rotate the cooling module so that the black release latch and handle are on the right side.
2. Slide the cooling module into its slot until the latch clicks home. The enclosure automatically detects
and uses the new unit.
Replacing a power supply unit (PSU)
The process involves removing the existing module and inserting a new one.
Removing a PSU
Important: Before removing a PSU, make sure you have a replacement module to insert.
1. Identify the PSU to be removed by using appropriate fault reporting software.
2. Ensure the other PSU has the “Power OK” LED lit.
3. Turn off the PSU to be removed.
4. Disconnect the AC power cord.
5. As shown in the following two figures, push the red release latch to the right and hold it (1), then pull
the module out by its handle (2).
Chapter 6. Module replacement 43
Summary of Contents for 084
Page 1: ...IBM ESS expansion Version 5 3 5 Installation and User Guide Model 084 IBM SC27462802...
Page 8: ...viii...
Page 14: ...xiv IBM ESS expansion Installation and User Guide Model 084...
Page 22: ...8 IBM ESS expansion Installation and User Guide Model 084...
Page 32: ...18 IBM ESS expansion Installation and User Guide Model 084...
Page 38: ...24 IBM ESS expansion Installation and User Guide Model 084...
Page 42: ...28 IBM ESS expansion Installation and User Guide Model 084...
Page 62: ...48 IBM ESS expansion Installation and User Guide Model 084...
Page 66: ...52 IBM ESS expansion Installation and User Guide Model 084...
Page 77: ......
Page 78: ...IBM SC27462802...