38
7.3.2 Weekly checks
Anti-condensate filter cleaning
: Check for condensate inside the anti-condensate filter
[1]
. If necessary,
open the manual-discharge plug
[A]
placed underneath the cup
[C]
of the filter. Blow-clean the filter
[E]
and
the internal pin
[F]
with compressed air from the inside to the outside.
Blast delivery adjustment screw seat cleaning
:
To clean the seat of the blasting material adjustment screw,
screw out and remove the nut
[M]
. Now clean the removed part and the hole
accepting the nut
[M]
with compressed air. Replace the nut
[M]
and the adjustment screw.
Blasting material/air mixing valve cleaning
: To clean the blasting material/air mixing valve, screw out the 4
nuts
[M]
and blow-clean the removed part with compressed air. After this, replace the galvanised block being
careful not to damage the screw and the screw seat threads.
1
C
A
E
F
M
1
E
Summary of Contents for 25
Page 4: ...3...
Page 10: ...9...
Page 22: ...21...
Page 26: ...25...
Page 30: ...29...
Page 31: ...30 ECO BLASTER IBIX 25 6 START UP 6 START UP page 30...
Page 33: ...32 E E E D D D A H B I J C G F...
Page 34: ...33...
Page 44: ...43...
Page 57: ...56 9 9 Conformity declaration n 493 ABR ORINOCO HP 14x25...