A Hard Reset reboots the computer inside your Newton.
Here is how to perform a hard reset:
Simultaneously press-hold the left, bottom, right, and center buttons. The screen
will go blank. Then, release the buttons and the Newton will restart.
All of your stored information will be retained, with the exception of date and time. Your
date and time will be reset automatically the next time you connect your Newton to your
ISAAC software.
FINE-TUNING THE NEWTON WIND SENSOR
The wind sensor is calibrated at the factory and generally does not need recalibration.
However, you can check the wind sensor calibration and correct its setting if desired. This
is advisable if you are using the Newton for advanced measurements such as CdA or Coast
Down or if you ride both in very cold and very hot conditions.
Here is what to do:
1)
Let your Newton acclimate to the temperature where you will be riding
2)
CRITICAL
: find a place where there is absolutely no wind blowing into the wind
port of your Newton, or cup your hand over the wind port so that wind is blocked
3)
Click on the bottom arrow twice until “wind” is shown in the top window:
4)
While on the wind screen,
PRESS-HOLD THE UP ARROW
, until the Cal Wind
screen appears:
5)
After seeing this screen, release the center button.
6)
Let the number at the top of the screen stabilize for 5 seconds
. It should
drift towards zero after a few seconds.
7)
Calibration is fine if the number is between -1.5 to + 1.5
8)
To re-calibrate, click the center button.
9)
The number in the top window will drift towards zero and after a few seconds the
Newton will return automatically to the main screen
CRITICAL
: MAKE SURE NO WIND IS BLOWING ON THE WIND PORT WHEN THE “CAL
WIND” CALIBRATION IS PERFORMED.