2.8.1 Wiring single-stage heating with a
boiler or combi boiler
Required if the boiler or combi does not have control of the pump.
Optional: 'G' for fan-only operation and 'C' for t-stat common.
Dry contact from the air handler to the boiler or combi boiler enables a call for heat.
Figure 36
Single-stage heating with a boiler or combi boiler wiring
Settings in the IBCconnect app
1. Tap
(menu icon), and select
Basic Settings
.
2. Set
Heat Mode
to
1 Stage Heat
.
3. Set
Cool Mode
to
No Cooling
.
4. Set
Boiler Heating
to
Boiler Only
.
5. Set
Tankless Mode
to
On
.
6. Tap
(SAVE).
37
2.8.1 Wiring single-stage heating with a boiler or combi boiler