Here you can enable or disable the signal.
10.3.4
EN50160 submodule: Flicker severity
“General” tab
Basic settings
See Power frequ
ency submodule, “General” tab, chapter 10.3.2
Configuration
To calculate the flicker, the lamp model to be used, 230 V or 120 V, has to be speci-
fied.
If the “Enable currents” option is “True” in the grid options, you need to indicate for each
conductor its impedance in Ohm.
“Analog” tab
Name
The names are assigned by default. To allow an unambiguous identification, they contain
the input channel, the characteristic value and the measurement interval.
Function
Calculation function used by ibaPQU-S.