5-2
5.
P
rev
ent
ive
/P
redi
ctiv
e
M
ai
nt
enanc
e
5.2 Maintenance information
This section introduces three items that can be configured and managed as maintenance
information.
When the set values are exceeded, a "maintenance warning" is issued and the status display
LEDs flash alternately in red and green.
Even if a "maintenance warning" is generated, the ELECYLINDER will continue to operate without
interruption.
Total travel count
Name
Symbol
Unit
Input range
Default setting
at shipping
Total travel count TMCT
times
0 to 999, 999,999
0
(disabled setting)
●
When the total travel count exceeds the set value, the user will be
notified with "Maintenance warning 1".
●
When "Maintenance warning 1" is output, maintenance is recommended,
such as greasing. Set the target value to a value larger than the present one
and update.
●
Setting it to "0 times" will disable this function.
Total travel distance
Name
Symbol Unit
Input range
Default setting
at shipping
Total travel distance
ODOT
m
0 to 999, 999,999
0
(disabled setting)
●
When the total travel distance exceeds the set value, the user will be notified
with "Maintenance warning 2".
●
When "Maintenance warning 2" is output, maintenance is recommended,
such as greasing. Set the target value to a value larger than the present one
and update.
●
Setting it to "0m" will disable this function.
●
The displayed units can be switched. (m
⇔
km)
5.2 Maintenance information
Summary of Contents for EC ELECYLINDER EC-RP4
Page 28: ...Intro 21...
Page 32: ...1 3 1 Specifications Product list Rod type Table type 1 1 Checking the product...
Page 60: ...1 31 1 Specifications...
Page 126: ...4 21 4 Operation...
Page 148: ...6 15 6 Parameters...
Page 198: ...11 3 11 Warranty...
Page 199: ...Appendix 12 1 Index 12 1 12 2 Revision history 12 5 ELECYLINDER Chapter12...
Page 206: ......
Page 207: ......