6.3. Continuous operation
This mode is used for applications that do not require asynchronous external trigger, but run in
continuous operation.
Mode setting and all other settings can be done via RS 232C control if rear switch SW1-10 is ON.
Mode setting and some other settings can be done by switch if rear switch SW1-10 is OFF.
For details: refer to “7. Configuring the Camera”.
To use this mode:
RS
SW1-
Set function: Trigger mode to “Normal”
TR=0
5, 6, 7 OFF
Shutter to “Normal” or “Programmable”
SM=0, SM=1
“Shutter speed”
SH=0 through 11
1, 2, 3, 4
“Programmable exposure”
PE=3 through 791
Other
functions
Input:
Ext. HD in on pin 6 on 12-pin connector. 4.0 Vp-p ±2.0V.
(If used).
Ext. VD in on pin 7 on 12-pin connector. 4.0 Vp-p ±2.0V.
(If used).
Important notes on using this mode
External sync system should follow the camera scanning system.
The ext. HD/VD phase relations should follow as shown in fig. 10.
1028
(h) effective pixels in continuous mode.
1016
(h) in trigger modes.
1ck = 40ns
Note!
1016ck in trigger modes
Fig. 11. Horizontal timing