62
—
AP-3200T-
PMCL
Item
Setting range
Default value
Description
SequencerReset
–
–
In [TriggerSequencerMode], reset
the current index number to the
number configured in
[SequencerSetStart].
k
) TransportLayerControl
Display information on transport
layer control.
ClConfiguration
Base, Medium, Full,
EightyBit
Medium
CameraLinkClockFrequendy
37.1MHz, 74.3MHz,
84.9MHzk
74.3MHz
n) JAICustomControl PulseGenerators
Configure pulse generator settings.
ClockPreScaler
1 to 4096
165
Set the division value for the
prescaler (12 bit) using PixelClock
as the base clock.
PulseGeneratorClock
(MHz)
0.018127 to 74.25
0.45
Set the clock used for the pulse
generator.
This value is calculated using the
[ClockPreScaler] value as a base.
PulseGeneratorSelector
PulseGenerator 0 to 3
PulseGenerator 0
Select the pulse generator.