50
—
AP-3200T-
PMCL
SequencerBlackLevelDigitalAll
-133 to 255
0
Set the black level value for
the selected
SequencerIndex.
Trigger Sequencer mode
With this mode, the Sequencer Trigger “pattern” is predetermined by the user. The user
defines up to 128 different “indexes.” The items indicated in the above index can be
configured for each index.
The operation of this mode is controlled using the following five commands.
[SequencerSetActive]
This allows you to confirm the currently configured index number.
[SequencerSetStart]
This configures the index number to execute at the start of TriggerSequencer mode.
[SequencerLUTMode]
This defines whether to apply gamma or LUT to the sequence.
When gamma is selected, the gamma setting defined in [AnalogControl] is applied to
all exposures in the sequence. When LUT is selected, the LUT characteristics defined in
[AnalogControl] are applied to indexes for which [SequencerLUT enable] is set to ON.
[SequencerReset]
During TriggerSequencer mode operation, this switches the index number to be executed to
Sample TriggerSequencer mode operation
User-defined Indexes (up to 128)
Index1
Index2
Index4
Index3
ROI
Exposure
Gain
LUT
Binning
Frame Count = 2
Next Index = 3
ROI
Exposure
Gain
LUT
Binning
Frame Count = 1
Next Index = 1
ROI
Exposure
Gain
LUT
Binning
Frame Count = 1
Next Index = 4
ROI
Exposure
Gain
LUT
Binning
Frame Count = 2
Next Index = 2
1
2
6
3
4
5
Triggers /
Image
Frames
1
Specify "1" in [SequencerSetStart], and start TriggerSequencer mode with
index 1.
2
Capture a 2-frame image with the first and second triggers.