63
seconds, the
IP Camera starts to record at 9:59:55.
Post-record:
The time you set to stop recording after the scheduled time or the event. For
example, if an alarm triggered recording ends at 11:00, and the
post-record time is set as 5
seconds, the
IP Camera records until 11:00:05.
Overwrite:
If you enable his function and the HDD is full, the new record files
overwrite
the oldest record files automatically.
Keep days:
If you enable his function a
nd the HDD is full, the n
ew record files will be
stop save into the HDD when the storage days over your setup volume of Keep days.
Make sure the size of storage media
allow to save video clips which setup volume of
“Keep
days”
mode.
Record path:
Select the recording media via
FTP server
or
SD card
.
To configure record settings, please make sure that you have the network storage
device within
the network or the SD card inserted in your IP camera.
“FTP server
”
: Setup the recording path via
FTP server
mode. The detail information of
FTP server, maybe need to ask the MSI people.
“SD Card
”
: Setup the recording path on SD Card.
You need to format the SD card from the IP camera before you used.