< 4.3 > QD Remote Control Connection & Operation
2.3 The configuration of the status code for both normal and alarm operations:
There are total 2 bytes of the status codes. Byte one, the first 8 bits, shows the current status of the operation
modes that the unit is in. Byte two, the second 8 bits, shows the current status of the alarm operations of the
unit.
BYTE1
BYTE 2
START
STOP
START
STOP
BYTE 1:
Status code for normal operation modes
b7
b6
b5
b4
b3
b2
b1
bO
LOCK VCR SEQU QUAD CH4
CH3
CH2
CH1
Channel
Select
1110 = CH1
1101 =CH2
1011 =CH3
0111 =CH4
Display Mode
0 = Quad screen display
1 = Full Screen display
Auto-sequencing mode
0 = Auto sequencing mode
1 = Quad or full screen mode
VCR mode
0 = VCR operation
1 = Live operation
Security Lock mode
0 = Security lock ON mode
1 = Security lock OFF mode
Menu Setup mode
00 = Menu setup mode
P.14