2. Unit Description
2.1. Front Panel Components
CLEAR
SET
PWR
ON
STATUS
RDY
DCD
ACTIVITY
1
2
3
4
5
6
www.wti.com
CMS-6R4
Console Management Power Control
1 2
3 4 5
6
Figure 2.1: Front Panel Components
As shown in Figure 2.1, the CMS-6R4 front panel includes the following
components:
Clear Button:
Restarts the CMS-6R4 operating program without
changing user-selected parameters or breaking port connections.
Power Indicator:
Lights when power is applied to the unit.
Set Button:
The Set Button has two functions; it can either be used as a
manual On/Off switch for the CMS-6R4's four switched outlets, or it can
also be used to initialize the unit to default parameters.
• Manual Switching:
To manually switch the outlets Off or On, press
and hold the Set Button for approximately three seconds. Note that
the Manual Switching function can also be disabled as described in
Section 5.5.1.
•
Initialization:
To initialize the unit to default parameters, press and
hold both the Set and Clear buttons, then release only the Clear Button,
wait for the Activity LEDs to flash, and then release the Set Button.
Notes:
• During initialization, all activity LEDs will flash ON three times.
• When the initialization procedure is performed, all command
selected parameters will be cleared, and the CMS-6R4 will revert to
default parameters.
RDY Indicator:
(Ready) Flashes when the unit is ready to receive
commands.
DCD Indicator:
Lights when the Data Carrier Detect signal is present.
Activity Indicators:
A series of six LEDs, which light to indicate data
activity at the corresponding port.