background image

11

Turn on the power of the extension unit

Important:

•  Connect the included power source cords to all the extension units and turn them on before turning on the recorder.

Step 1

Connect the included power cord to the power cord 
inlet on the rear panel of the extension unit, and insert 
the power plug to an outlet whose rating is as follows.

100 V - 240 V AC, 50 Hz/60 Hz

Important:

•  Insert the power cord fully into the power cord inlet so 

that it will not loosen or come out.

•  Fix the power cord firmly at 15 cm to 20 cm {5-7/8 to 

7-7/8 inches} from the plug with the included power 
cord clamp to prevent the cable from unplugging.

How to fix the power cord

Fix the power cord at 15 cm to 20 cm {5-7/8 to 7-7/8 inches} 
from the connector with the included cable clamp (for power 
cord) passed through the clamp mount.
Fix the power cord so that it does not block the cooling fan 
outlet.

Clamp mount

Power cord clamp

 Pass the power cord clamp through the clamp mount.

 Make a ring with the power cord clamp as shown in the 
illustration to tighten the power cord.

15 cm to 20 cm 
{5-7/8 to 7-7/8 inches}

 Tighten the power cord at 15 cm to 20 cm {5-7/8 to 7-7/8 
inches} from the connector and fix it to the clamp mount. 
Cut the unnecessary part of the power cord clamp as 
necessary.

Step 2

Press the POWER switch on the rear of the extension 
unit to turn on the power.

•  The OPERATE indicator will light and the system check 

(checking the system and hard disk drives) will start.

•  The "Initializing" indication will be displayed on the LCD at 

startup.

•  When the system check is complete, the operational mode 

and temperature will be displayed on the LCD.

3

 Turn on the devices

(When turn off the power of the extension unit)

Follow the procedure below to turn off the power.
If multiple extension units are connected, turn off them in an arbitrary order.

Step 1

Stop recording on the recorder.

•  Stop all recordings on the network disk recorder.
•  Stop all playbacks.

Step 2

Turn off the power of the recorder.

Step 3

Turn off the power of the extension unit.

Important:

•  Turn off the power of the extension unit after turning 

off the power of the recorder.

Summary of Contents for WJ-HXE410 Series

Page 1: ...er is abbreviated in some descriptions in this manual Installation Guide Extension Unit Model No WJ HXE410 Series The Operating Instructions and Important Information is on our support website https i...

Page 2: ...the HDD units from extension unit Remove the extension unit from recorder Others Specifications 2 Contents Introduction 3 Standard accessories 3 About the user manuals 3 About the symbol mark 3 About...

Page 3: ...ment may differ from the actual product within no influence range on operation due to improvement of the product The explanation of the symbol marks used in this product are as follows Alternation cur...

Page 4: ...h Locations subject to steam and oil smoke such as a kitchen Locations which are not level Locations subject to dust Locations where it may get wet from rain or water splash Do not install this produc...

Page 5: ...s fluorescent lamps noises may be produced In this case rewire avoiding the noise sources or move the product to a place far from the source Grounding Confirm that the wire is connected from the SIGNA...

Page 6: ...order and install the HDD unit The removed HDD unit holding bracket is necessary when transporting the recorder Keep it in an appropriate place Professional knowledge on and experience in network and...

Page 7: ...1U 44 mm 1 23 32 inches between the top and bottom of the product Do not put doors on the front of the rack or block the sides The recorder weighs over 10 kg 22 1 lbs Be careful not to drop the record...

Page 8: ...ce of 1 unit Require a space of 1 unit Connection cable included in extension unit Extension unit Unit number 1 Extension unit Unit number 2 Extension unit Unit number 3 Extension unit Unit number 4 E...

Page 9: ...mber 1 Extension unit unit number 2 Extension unit unit number 3 Extension unit unit number 4 Extension unit unit number 5 Attach a cable clamp to each connection cable Attach a cable clamp to each co...

Page 10: ...p 2 Close the clamp Step 3 Slide the cable clamp toward the connector end of the connection cable and then hold the connector end of the connection cable Make sure that the connection cable is connect...

Page 11: ...ake a ring with the power cord clamp as shown in the illustration to tighten the power cord 15 cm to 20 cm 5 7 8 to 7 7 8 inches Tighten the power cord at 15 cm to 20 cm 5 7 8 to 7 7 8 inches from the...

Page 12: ...ding strap etc Even after releasing static electricity hold the side of the hard disk drive when carrying it To prevent damage to the hard disk drive from static electricity do not touch the circuit b...

Page 13: ...starting from HDD1 Lift up the lever on the HDD unit while holding down the removal knob and then insert the HDD unit all the way into the HDD slot Insert the HDD unit carefully without knocking it a...

Page 14: ...t first 11 When using a circuit breaker or equivalent device to turn on off the power of the whole system at one time make sure that all devices are connected to the same power source When using an UP...

Page 15: ...s damaged The power cord connector or power plug is damaged This may result in electric shock or a fire Unplug the power plug from the AC outlet immediately and refer to qualified service personnel Th...

Page 16: ...nt For more information about collection and recycling please contact your local municipality Penalties may be applicable for incorrect disposal of this waste in accordance with national legislation N...

Reviews: