Hardware Manual
BMS Master 4 / 4.5
Ref.: IR14417 A 15.01.2018
Page 59/76
Attention:
The mounting holes do NOT comply with the
requirements of 10 mm air and creepage distances for high
voltages.
If the slave modules are used under these conditions non-
conductive screws and/or bolts must be used.
3.6.7.3
S
UPPLY AND
C
URRENT
C
ONSUMPTION
The SL6_CON module must be powered from the BMS Master.
Description
Value
Unit
Voltage
9…16
V
Current (Master active)
≤ 100
mA
Current (Master active max.)
≤ 150
mA
3.6.7.4
E
NVIRONMENTALS
Environmental testing:
Temperature Test acc. ISO16750-4:
o
24 h @ – 40 °C
o
96 h @ +85 °C
o
4 x cycles at -40°C and 85°C
Insulation test: 300GΩ / 5kV DC.
EMC:
acc. EN 55022 and EN 55024 (industrial)