Page 29/76
of twisted pair cables is required. The shield is connected to the BMS Master only.
3.2.2.4
C
ONNECTING THE
BAT-S
1000
1U
SENSOR FOR VOLTAGE MEASUREMENT
For voltage measurement the 2-pole MicroFit-connector is used. The two pins are shorted
internally. The voltage measurement uses one side of the shunt as reference (see
3.2.2.1).
3.2.2.5
T
ECHNICAL
S
PECIFICATION
BAT-S
1000
1U
-
S
ENSOR
Environmental Temp Range
-40 / +85 °C
Current Meas. Range nominal
± 470 A
Current Meas. Range ext.
± 1200 A, max. 5 minutes
Offset
± 15 mA
Physical Resolution
15 mA nominal, 37 mA extended
Voltage Meas. Range nominal
± 1200 V
Physical Resolution
50 mV
Temperature Meas. Range
-40 / +105 °C
Physical Resolution
0.1 °C
For further and detailed information on the BAT-S1000 1U refer to the product
specification by ACTIA I+ME GmbH.
The maximum current depends on the mechanical position and the heat dissipation
conditions. The high current cables connected provide a heat sink for the shunt. The
connections have to be made with a minimum contact resistance. The cable have to
be over dimensioned to achieve proper heat dissipation.
The inner heat resistance is approx. 2 K/W, the resistance is approx. 25µ
Ω
and the
nominal power is approx. 15W. Ensure that under worst case operating conditions a shunt
temperature of 85 °C is not exceeded.
Summary of Contents for BMS Master 4
Page 73: ...Hardware Manual BMS Master 4 4 5 Ref IR14417 A 15 01 2018 Page 73 76 6 CERTIFICATES...
Page 74: ...Hardware Manual BMS Master 4 4 5 Ref IR14417 A 15 01 2018 Page 74 76...
Page 75: ...Hardware Manual BMS Master 4 4 5 Ref IR14417 A 15 01 2018 Page 75 76...
Page 76: ...Hardware Manual BMS Master 4 4 5 Ref IR14417 A 15 01 2018 Page 76 76...