Hardware Manual
BMS Master 4 / 4.5
Ref.: IR14417 A 15.01.2018
Page 35/76
12 11 10 9 8 7 6 5 4 3 2 1
10-cell-wiring
Z
1
0
+
Z
1
-
3.4.4.
F
UNCTIONAL
D
ESCRIPTION
3.4.4.1
P
OWER
S
UPPLY
The CPU and peripherals are supplied by linear regulated 5VDC derived from the mid cell
voltages number 6 to 8, min. 5.4V to 12.6V, connected to cell contacts 7 … 10.
The power supply reference level is always at cell contact 7.
3.4.4.2
S
INGLE
C
ELL
I
NTERFACE
The interface to the single battery cells is realized as 12 edge connector pads suitable for an
edge connector ZEC1, 0/12 made by Phoenix Contact (Order No. 18 93 78 2), additionally
12 solder pads in a 3,5mm-pitch for 10 cells with 11 connections; order with contact row at
top of board; pin1 is the last one right of the coding slot.
12
11
10
9
8
7
6
5
4
3
2
1
ce
ll 10
+
ce
ll 9
+
ce
ll 10
–
ce
ll 8
+
ce
ll 9
–
ce
ll 7
+
ce
ll 8
–
ce
ll 6
+
ce
ll 7
–
ce
ll 5
+
ce
ll 6
–
ce
ll 4
+
ce
ll 5
–
ce
ll 3
+
ce
ll 4
–
ce
ll 2
+
ce
ll 3
–
ce
ll 1
+
ce
ll 2
–
ce
ll 1
–
n.
c.
The edge connector provides pre-mating contacts to assure the proper connecting
sequence. Do only connect the single cell voltages to the edge connector, when it is not
plugged.
Attention:
If
NOT
using the edge connector, the single cells have
to be connected in a
proper sequence
to avoid damage to the multiplexers on the slave module. The
cells can be connected in two ways:
-
either by soldering the wires directly into the pad holes
-
or by using pin rows in 3.5 mm pitch in conjunction with pluggable miniature spring
cage clamps (e.g. PHOENIX CONTACT PST 1,0/12-3,5 (Order No. 19 45 19 3) with
clamps FK-MPT 0,5/12-ST-3,5 (Order No. 19 14 03 0))
For Phoenix connector details see product catalogue or visit www.phoenixcontact.com.
The following sequence must be strictly observed:
1.
contact 12
2.
contact 6
3.
contact 9
4.
contact 2
5.
contact 7
6.
the remainder in any order
To remove the slave from the battery, disconnect in
reverse order.
Summary of Contents for BMS Master 4
Page 73: ...Hardware Manual BMS Master 4 4 5 Ref IR14417 A 15 01 2018 Page 73 76 6 CERTIFICATES...
Page 74: ...Hardware Manual BMS Master 4 4 5 Ref IR14417 A 15 01 2018 Page 74 76...
Page 75: ...Hardware Manual BMS Master 4 4 5 Ref IR14417 A 15 01 2018 Page 75 76...
Page 76: ...Hardware Manual BMS Master 4 4 5 Ref IR14417 A 15 01 2018 Page 76 76...