Chapter 2 - Specifications
0818D
User’s
Guide
2-6
•
This monolithic backplane has 2 segments of H.110 bus. One
H.110 bus exists on slots #2 through #8. The other H.110 bus
exists on slots #10 through #16.
•
The backplane includes two standard fabric slots (#17 and
#18) according to PICMG 2.16 and two 8-slot cPCI bus
segments, each with one system slot (#1 and #9) and seven
peripheral slots. The system and peripheral slots are standard
dual nodes according to PICMG 2.16.
2.2.4.1 cPCI Backplane
•
The cPCI backplane includes two independent segments of 8-
slot cPCI connectors.
•
The cPCI backplane includes power supply connectors to the
power supply modules (47 pin connector to each module) and
power distribution to all slots.
•
DC main input to the power supply section of the backplane is
be through the DC Input module system.
•
The cPCI backplane provides a connector behind the Power
Supply section for the purpose of connecting a stand-alone
CMC (Chassis Management Controller) board.
•
The cPCI backplane incorporates six sets of fan control
signals, originating on the CMC connector. Each set of fan
control signals includes: FANTACH or LKROTOR, 12VDC
(PWM), GND.
•
The cPCI backplane incorporates a continuous IPMB0 bus
from the CMC connector to all 18 cPCI slots.
•
The cPCI backplane provides local I2C bus from the CMC
connector pins to two locations in the upper portion of the
backplane and one location in the lower left corner of the
backplane for the purpose of connecting I2C sensor
components at strategic locations within the enclosure.
2.2.4.2 Backplane CMC Connector
•
Chassis Management Controller (CMC) is optional to the
system enclosure.
Summary of Contents for 0818D
Page 1: ...0818D User s Guide Doc No 1002830 Rev 3 User s Guide 0818D CompactPCI System ...
Page 3: ...0818D User s Guide 3 ...
Page 9: ...Table of Contents 0818D User s Guide 9 This page was intentionally left blank ...
Page 10: ......
Page 12: ...Chapter 1 Introduction 0818D User s Guide 1 2 This page was intentionally left blank ...
Page 22: ......
Page 36: ...Chapter 3 Hardware 0818D User s Guide 3 14 This page was intentionally left blank ...
Page 42: ...Chapter 4 Power Distribution 0818D User s Guide 4 6 This page was intentionally left blank ...
Page 44: ...Chapter 5 Software 0818D User s Guide 5 2 This page was intentionally left blank ...
Page 62: ......
Page 78: ...Appendix 3 Limited Warranty 0818D User s Guide A3 2 This page was intentionally left blank ...
Page 80: ...Appendix 4 FCC Information 0818D User s Guide A4 2 This page was intentionally left blank ...