19
DC Operation
Do not leave generator unattended when charging batteries. Stop charging when
the voltage of the batteries is above 16V. Failure to monitor charge level may result in
damage to the battery or personal injury.
The DC receptacle may be used while the AC power is in use.
The overloaded DC circuit will trip the DC circuit protector. If this happens, disconnect
the DC load before pushing in the circuit protector to resume operation.
1.
Set the ECON switch to the OFF position.
2.
Connecting the battery charging cable.
•
Connect the battery charging cable to the battery.
•
Plug the charging wires into the DC outlet of the generator.
•
Connect the positive (Red) terminal of the charging wire to the positive
(+) battery terminal and negative (black) terminal of the charging wire to
the negative (-) battery terminal.
3.
Turn the start switch to the ON position.
4.
Set the DC breaker switch to ON position (refer to fig.).
5.
Start the generator.
NOTICE
•
The DC socket is only used for charging a 12V battery.
•
When using the DC socket, turn the ECON switch to the OFF position.
WARNING
•
The battery gives off explosive gases; keep sparks, flames and cigarettes away.
Provide adequate ventilation when charging or using batteries.
•
Battery posts, terminals, and related accessories contain lead components.
Wash hands after handling.
An overloaded DC circuit, excessive current draw by the battery, or a wiring problem will
automatically trip (turn off) the DC breaker switch. If this happens, wait a few minutes
before pressing the breaker switch to the ON position to resume operation. If the
breaker switch continues to go OFF, discontinue charging and contact your authorized
dealer.
Summary of Contents for GreenPower
Page 1: ...HYUNDAI PORTABLE INVERTER USER GUIDE ...
Page 36: ...36 ...
Page 38: ...38 ...
Page 39: ...39 Enjoy Be sure to check www hyundaipower ca for updates regarding your generator ...
Page 40: ......
Page 41: ...HYUNDAI ONDULEUR PORTATIF MANUEL D UTILISATION ...
Page 78: ...38 ...
Page 80: ......