background image

06 

5. Installation Debugging and Operation

Input cable connection (enclose installing diagram) 
1) Every machine has been equipped with a power cable which must be connected to coordinate voltage 

class in compliance with input voltage of cutting machine. 

2) Make sure power cable is connected to power switch reliably and prevent from oxidizing. Make sure power 

voltage is in the waved range. 

Output cable connection 
1) Make sure tube of pressed air is connected to copper connector by high pressure rubber tube fiITnly. 
2) Make sure copper screw of another end of torch is connected to electrify integrated teITninal and then 

tighten them clockwise (to prevent from leaking gas). Make sure plug of another end of grounding cable 
pincer is connected to positive terminal on front panel then tighten it. 

3) Make sure air plug of torch is connected to switch connector of panel (If it is arc-supporting cutter, arc-sup­

porting cable of torch is connected to teITninal of arc-supporting). 

Check 
1) Check if cutting machine is grounded reliably according to standard. 
2) Check if all connectors are connected firmly. 
3) Check if power voltage is correct. 

Operation 
1) Open the power switch of front panel, make the power switch is "on" position. At this time indicator of 

power switch is on. Screen will show the current volume. 

2) Adjust the gas pressure and make it adequate to machine, open the valve of pressed air. 
3) Press the control knob of torch, electromagnetic valve is starting, sound of HF arc-tricking can be heard 

and burner of torch should flow out gas (Burner of arc-supporting cutter should spurt fire) 

4) Make sure cutting current is adequate to machine according to thickness of cutting piece. 
5) It is I mm from copper tip to work piece 

Ot 

is further if it is arc-supporting cutter.), press knob of torch and 

strike arc. Sparks of HF arc-striking will diminished immediately .User can begin to cut. 

Instruction Notes 
Operation environment 
1) The cutting machine can perform in environment where conditions are particularly harsh and with outside 

temperature between -10 and +40 degrees Celsius with a dampness level of max 80%. 

2) Avoid using in sunshine and rainy environment. 
3) Keep machine dry and avoid water into machine. 
4) Do not use the cutting machine in environment where is polluted with high density of dust or corrosive gas 

in the air. 

HYUNDAI 

CUT-

401 

Summary of Contents for CUT- 401

Page 1: ...DC INVERTER PLASMA CUTTER CUT 401 User Manual Original Instructions HYUNDAI EN CE For Your Safety Read and understand this manual before use Keep this manual for future reference...

Page 2: ...improving this welder therefore some parts of this welder may be changed in order to achieve the better quality but the main functions and operations will not be alternated and changed Your understand...

Page 3: ...Contents Safety General Description CUT 401 2 4 Main Parameters 4 Operation Control and Description 5 Installation Debugging and Operation Caution Maintenance Troubleshooting 6 7 8 9 Exploded Drawing...

Page 4: ...clothes Make sure that you are insulated from the ground and work piece Make sure that your working position is safe Smoke gas may be harmful to health Keep the head away from smoke and gas to avoid...

Page 5: ...nderstand after reading the manual or still cannot solve the problem according to the manual Safe use of the welding torch Parts of the machine such as the end of the filler wire and welding torch bec...

Page 6: ...ction that it can supply gas ahead and turn off gas delayed The cutting machine has characteristics as following 1 Stabilizing 2 Reliability 3 Lightness 4 Save energy and no noise 5 High cutting speed...

Page 7: ...ove is for reference only If any difference with the real machine please follow with the real machine HYUNDAI CUT 401 Power indicator Power switch gas electric Air plug intergrated connector CUT 401 T...

Page 8: ...ectors are connected firmly 3 Check if power voltage is correct Operation 1 Open the power switch of front panel make the power switch is on position At this time indicator of power switch is on Scree...

Page 9: ...safety if the ma chine has no cable for plug This is not necessary for the machine with Euro plug or others with grounding cable already 5 Inner component of heat adjustment starts to work if machine...

Page 10: ...sure that there is no problem the machine can be operated 5 If the machine is not used for long time it should be put in its own packing box and stored in dry environment Correct Disposal of this prod...

Page 11: ...d Switch indicator is lit and fan is working However once pressing control 2 Check the transformer on bottom board whose function is to increase knob of torch there is no HF arc striking sound and int...

Page 12: ...rewM4 20 27 Silicon bridge 28 Switch board 29 ScrewM3 6 30 Middle board 31 Arcing coil 32 Radiator 33 Radiator 34 Radiator 35 Radiator 36 PCB fix board 37 Screw fixer 2 38 ScrewM5 39 Firming fixer 40...

Page 13: ...11 HYUNDAI CUT 401...

Page 14: ...NVERTER PLASMA CUTTER MODEL CUT 401 Satisfies the requirements of the Council Directives EC Low voltage directive 2014 35 EU EC Directive of Electromagnetic Compatibility 2014 30 EU RoHS Directive 201...

Page 15: ......

Page 16: ...HYUNDAI Corporation 25 Yulgok ro2 gil Jongno gu Seoul 03143 Korea Post Code 03143 8223901114 www hyundaicorp com Copyright HYUNDAI Corporation All rights reserved Made in P R C HYUNDAI...

Reviews: