12
Alarm
Code
Alarm Name
Description
H1
Coprocessor over-temperature alarm
The repeater fails to work. At this time, if the Repeater
Backup feature is enabled on the CPS, the repeater starts a
backup.
H3
Network IP conflict alarm
Network services of the repeater are unavailable.
5.1 Low Forward Power Alarm
5.1.1 Description
When the repeater detects that the TX power is below the preset value of forward power, the alarm indicator glows
red and the alarm code Eb appears on the display.
At this time, the repeater stops transmission.
5.1.2 Solution
Check whether the RF adapter cable, antenna, or feed line is properly connected.
If yes, contact your local dealer for technical support.
If no, re-connect or replace the cable, antenna, or feed line.
5.2 TX/RX Unlocked Alarm
5.2.1 Description
When the repeater detects that the TX PLL or RX PLL is unlocked, the alarm indicator glows red and the alarm code
E4 or E5 appears on the display.
At this time, the repeater automatically fails to provide certain features.
5.2.2 Solution
1.
Disconnect the power supply, and then open the housing.
2.
Check whether all the cables are properly connected.
If yes, contact your local dealer for technical support.
If no, re-connect or replace the cable.