background image

HYPRO WATER – 05.2021

34

3.10 / 11 

 

y

Screw the knurled screw (N) through 
the wall bracket (C) into the device 
from below.

3.10 / 12 

 

y

Slide the reducer piece (F) into the 
connection piece (H) until the endpoint 
is reached.

 

y

Secure the reducer piece (F) with the 
safety clip (M).

3.10 / 13 

 

y

Screw the connection piece (G) onto 
the tap connection for cold water by 
hand.

3.10 / 14 

 

y

 Guide both hoses from the device to 
the connection piece (G) and reducer 
piece (F) respectively.

 

y

Mark the respective hose length 
required.

 

y

Shorten both hoses to the required 
lengths. Make sure the hoses are 
trimmed straight.

Summary of Contents for HYPRO WATER

Page 1: ...User manual HYPRO WATER EN 05 2021 ...

Page 2: ...a dangerous situation that can lead to death or serious injury D CAUTION Information marked with the word CAUTION warns of a dangerous situation that can lead to minor or moderate injury D ATTENTION Information marked with the word ATTENTION warns of a situation that can lead to damage to property or the environment ...

Page 3: ...llation variant 1 17 3 8 Executing installation variant 2 21 3 9 Executing installation variant 3 26 3 10 Executing installation variant 4 31 3 11 Inserting the filter 35 3 12 Completing installation 37 4 Use 39 5 Cleaning 40 6 Maintenance 41 6 1 Changing the filter 41 6 2 Check 42 7 Troubleshooting 43 8 Disassembly 45 9 Disposal 46 9 1 Disposing of the packaging 46 9 2 Disposing of used filters 4...

Page 4: ...serving this user manual In a technically faultless and unmodified condition With the use of new original accessories After correct installation and checks In enclosed rooms Any other use is non intended use 1 2 User Requirements applicable to the user Knowledge of this user manual Experience of using mechanical tools Special requirements apply to the following users Children from 8 years Persons ...

Page 5: ...This results in a risk of electric shock y Make sure that the electrical connection is protected with an RCD max 30 mA y Never submerge the device in water or other liquids y Never take hold of the power plug with wet hands y Always hold the power plug by the plug enclosure y Do not pull on the mains cable y Never carry the device by the mains cable y Do not bend the cable y Do not crush the cable...

Page 6: ...device or individual components are damaged In case of unauthorised modifications or changes to the device If the device is malfunctioning The manufacturer accepts no liability for damages in the following cases With a failure to observe this user manual In case of non intended use In case of incorrect handling With use of non original accessories Made in Germany The device and its installation ar...

Page 7: ...device cleanses water of Bacteria viruses and parasites Medications and hormones Pesticides and herbicides Heavy metals Chlorine chloramines and trihalomethanes Volatile organic compounds Per and polyfluoroalkyl compounds e g PFOA and PFOS Odorants and flavourings Tested and verified by independent laboratories 2 2 Product overview 5 3 4 6 2 2 1 2 7 1 1 Device cover 2 Pressure point of the device ...

Page 8: ... 72 73 The LED indicator signals the operating statuses of the device to the user 71 LED lights up green The device is ready 71 LED lights up blue The device is disinfecting 72 LED flashes yellow The device is ready for a WLAN connection 72 LED lights up yellow continuously The device is connected with the WLAN 73 LED lights up or flashes red Fault or filter change ...

Page 9: ...et D Angle piece 5 16 E Angle piece 3 8 F Reducer piece G Connection piece outside thread 3 8 H Connection piece inside thread 3 8 I Water inlet hose 5 16 J Water discharge hose 3 8 K T piece including shut off valve L 4 safety clips 5 16 M 5 safety clips 3 8 N Knurled screw O 4 screws for mounting on chipboard P User manual ...

Page 10: ... on the filter type and operating pressure used 2 5 HYPRO WATER app The HYPRO app must be downloaded from an app store in order to connect the device to a smartphone or tablet System requirements Smartphone or tablet Android version 5 0 or more recent Smartphone or tablet iOS version 8 0 or more recent Android iOS You can find the app in the respective app store under the name HYPRO WATER App The ...

Page 11: ...or behind the worktop through which the mains cable and hoses are routed If the wall bracket is used Select the installation site such that 10 cm remains clear beneath the device for mounting on the wall bracket Select the installation site such that 20 cm remains clear above the device to facilitate a filter change If the device is used with the HYPRO app A WLAN connection to the internet must be...

Page 12: ...rts with care y Check the device and all enclosed parts for damage y Check the scope of supply for completeness 2 3 Scope of supply page 9 If parts are damaged or missing y Contact your customer service centre 10 1 Customer service centre contact details page 47 y Remove the packaging materials 9 1 Disposing of the packaging page 46 In individual cases a small amount of water may be present in the...

Page 13: ...ssories The user manual presents four possible installation variants of the device y Choose the installation variant appropriate in your application case 3 4 Installation variants page 14 y Install the HYPRO app 3 3 1 y Assemble the required tools and materials Bucket Cutter blade Pen Spirit level Screwdriver Pipe wrench Cut resistant underlay Angle pieces are only required if you mount the device...

Page 14: ... Installation variant 2 3 4 2 Connection to an auxiliary tap and use of a 2 way tap 3 8 Executing installation variant 2 page 21 Installation variant 3 3 4 3 Connection to a 2 way tap 3 9 Executing installation variant 3 page 26 Installation variant 4 3 4 4 Connection to a 2 way tap and use of a boiler 3 10 Executing installation variant 4 page 31 ...

Page 15: ...all bracket C with the spirit level y Mark the four fastening points Use fastening materials that are suitable for the installation D WARNING Danger due to explosion or electric shock Drilling into gas water or electrical lines can result in dangerous situations y Make sure no lines are present in the wall at the fastening points 3 5 2 y Screw on the wall bracket C with the four screws O ...

Page 16: ...he hose y Insert the hose until the endpoint is reached The retainer element secures the hose Make sure you do not deform the hose 3 6 3 Check the connection y Check the connection by pulling against it 3 6 4 Release the connection y Check that the system is pressure free y Push back the retaining element with the fingers or with a release aid and hold it firmly y Remove the inserted hose ...

Page 17: ... installation variant 1 3 7 1 20 cm 10 cm C I A K B L D J G H M E 3 7 2 N O y Assemble the required parts If installing without the wall bracket then C D E N and O are omitted Connection pieces G and H alternatively depending on the tap used ...

Page 18: ...f the tap from the angle valve 3 7 5 y Screw the T piece K onto the angle valve of the cold water pipe y Screw the opposite side of the T piece K to the cold water connection of the tap y Make sure that the valve of the T piece K is closed y Remove the bucket 3 7 6 y Insert the angle piece D in the water inlet left until the endpoint is reached y Secure the angle piece D with the safety clip L ...

Page 19: ...e piece E in the water outlet right until the endpoint is reached y Secure the angle piece E with the safety clip M 3 7 9 y Insert the hose J in the angle piece E until the endpoint is reached y Secure the hose J with the safety clip M 3 7 10 y Guide the mains cable and hoses from above through the cut out in the wall bracket C y Place the device on the wall bracket C ...

Page 20: ...ctively y Mark the respective hose length required y Shorten both hoses to the required lengths Make sure the hoses are trimmed straight 3 7 11 y Screw the knurled screw N through the wall bracket C into the device from below 3 7 12 y Screw the connection piece H or G onto the tap for disinfected water by hand ...

Page 21: ...Secure the hose I with the safety clip L 3 7 15 y Insert the hose J in the connection piece H or G until the endpoint is reached y Secure the hose J with the safety clip M Continue with chapter Inserting the filter 3 11 Inserting the filter page 35 3 8 Executing installation variant 2 3 8 1 20 cm 10 cm ...

Page 22: ...e wall bracket then C D E N and O are omitted Connection pieces G and H alternatively depending on the tap used 3 8 3 y Turn the angle valve on the cold water pipe to close it 3 8 4 y Place a bucket beneath the angle valve on the cold water pipe y Unscrew the cold water connection of the tap from the angle valve ...

Page 23: ... is closed y Remove the bucket 3 8 6 y Insert the angle piece D in the water inlet left until the endpoint is reached y Secure the angle piece D with the safety clip L 3 8 7 y Insert the hose I in the angle piece D until the endpoint is reached y Secure the hose I with the safety clip L 3 8 8 y Insert the angle piece E in the water outlet right until the endpoint is reached y Secure the angle piec...

Page 24: ...the safety clip M 3 8 10 y Guide the mains cable and hoses from above through the cut out in the wall bracket C y Place the device on the wall bracket C 3 8 11 y Screw the knurled screw N through the wall bracket C into the device from below 3 8 12 y Screw the connection piece H or G onto the tap for disinfected water by hand ...

Page 25: ...o the required lengths Make sure the hoses are trimmed straight 3 8 14 y Insert the hose I in the T piece K until the endpoint is reached y Secure the hose I with the safety clip L 3 8 15 y Insert the hose J in the connection piece H or G until the endpoint is reached y Secure the hose J with the safety clip M Continue with chapter Inserting the filter 3 11 Inserting the filter page 35 ...

Page 26: ...TTENTION Non disinfected hot water if connected to a 2 way tap without boiler Hot water cannot be disinfected y To draw off disinfected water when connected to a 2 way tap without a boiler make sure that the mixer tap is fully in the cold position 3 9 1 20 cm 10 cm ...

Page 27: ...red parts If installing without the wall bracket then C D E N and O are omitted 3 9 3 y Turn the angle valve on the cold water pipe to close it 3 9 4 y Place a bucket beneath the angle valve on the cold water pipe y Unscrew the cold water connection of the tap from the angle valve ...

Page 28: ...D in the water inlet left until the endpoint is reached y Secure the angle piece D with the safety clip L 3 9 7 y Insert the hose I in the angle piece D until the endpoint is reached y Secure the hose I with the safety clip L 3 9 8 y Insert the angle piece E in the water outlet right until the endpoint is reached y Secure the angle piece E with the safety clip M ...

Page 29: ...hrough the cut out in the wall bracket C y Place the device on the wall bracket C 3 9 11 y Screw the knurled screw N through the wall bracket C into the device from below 3 9 12 y Slide the reducer piece F into the connection piece H until the endpoint is reached y Secure the reducer piece F with the safety clip M 3 9 13 y Screw the connection piece G onto the tap connection for cold water by hand...

Page 30: ...to the required lengths Make sure the hoses are trimmed straight 3 9 15 y Insert the hose I in the reducer piece F until the endpoint is reached y Secure the hose I with the safety clip L 3 9 16 y Insert the hose J in the connection piece G until the endpoint is reached y Secure the hose J with the safety clip M Continue with chapter Inserting the filter 3 11 Inserting the filter page 35 ...

Page 31: ... WATER 05 2021 31 3 10 Executing installation variant 4 3 10 1 20 cm 10 cm C I A H B L D J F G M E 3 10 2 N O y Assemble the required parts If installing without the wall bracket then C D E N and O are omitted ...

Page 32: ...y Turn the angle valve on the cold water pipe to close it 3 10 4 y Place a bucket beneath the angle valve on the cold water pipe y Unscrew the cold water connection of the tap from the angle valve 3 10 5 y Screw the connection piece H onto the angle valve of the cold water pipe by hand y Remove the bucket 3 10 6 y Insert the angle piece D in the water inlet left until the endpoint is reached y Sec...

Page 33: ...e piece E in the water outlet right until the endpoint is reached y Secure the angle piece E with the safety clip M 3 10 9 y Insert the hose J in the angle piece E until the endpoint is reached y Secure the hose J with the safety clip M 3 10 10 y Guide the mains cable and hoses from above through the cut out in the wall bracket C y Place the device on the wall bracket C ...

Page 34: ...endpoint is reached y Secure the reducer piece F with the safety clip M 3 10 13 y Screw the connection piece G onto the tap connection for cold water by hand 3 10 14 y Guide both hoses from the device to the connection piece G and reducer piece F respectively y Mark the respective hose length required y Shorten both hoses to the required lengths Make sure the hoses are trimmed straight ...

Page 35: ...clip L 3 10 16 y Insert the hose J in the connection piece G until the endpoint is reached y Secure the hose J with the safety clip M 3 11 Inserting the filter 3 11 1 y Take off the device cover To do so press down on the pressure point and then reach beneath the edge of the device cover 3 11 2 y Turn the shut off valve into the CLOSE position ...

Page 36: ... cap off the filter chamber 3 11 4 y Remove the protective film from the filter B y Insert the filter B y Carefully press the filter B down until it latches into the device 3 11 5 y Turn the screw cap on the filter chamber until it is fully closed ...

Page 37: ...he device with the WLAN y Follow the instructions of the HYPRO WATER app 2 5 HYPRO WATER app page 10 When the device is connected with the WLAN the middle LED will be constantly lit up yellow To search again y Unplug the power plug and plug it back in again y Wait until the middle LED flashes yellow Installation variants 1 and 2 3 12 2 y Open the shut off valve of the T piece K y Open the angle va...

Page 38: ...articles do not have an adverse effect on personal health y Open the disinfected water tap and allow the water to run for around 180 seconds y Allow the disinfected water to flow through until no further particles flow out although for at least 180 seconds After installation and first commissioning check y The connection points for any water leaks by way of a visual inspection ...

Page 39: ... unable to perform self cleaning The quality of the disinfected water may be impaired y Allow the disinfected water to run for 180 seconds before using it Drawing disinfected water y Draw filtered and disinfected water as required G1 4 1 G2 G3 The LED indicator signals the operating statuses of the device to the user G1 LED lights up green The device is ready G1 LED lights up blue The device is di...

Page 40: ...TER 05 2021 40 5 Cleaning Information about cleaning y Clean the surfaces of the device with a lint free cloth slightly dampened with water y Rub the surfaces of the device with a dry lint free cloth to dry it ...

Page 41: ...point for the filter change y Take off the device cover 3 11 1 page 35 y Turn the shut off valve in the CLOSE direction Never open the screw cap for the filter chamber when pressurised 3 11 2 page 35 6 1 1 y Open the tap for disinfected water until no further water flows out of the tap y Close the disinfected water tap again to prevent a backflow of water D ATTENTION Water leaking out Water can ru...

Page 42: ...wn until it latches into the device 3 11 4 page 36 y Turn the screw cap for the filter chamber to close it 3 11 5 page 36 y Turn the shut off valve in the OPEN direction 3 12 4 page 38 y Fit the device cover 3 12 5 page 38 y Open the disinfected water tap and allow the water to run for at least 180 seconds until particles no longer flow out 3 12 6 page 38 6 2 Check y Make sure no water is able to ...

Page 43: ...e left LED does not light up blue although water is flowing Device has a fault y Unplug the power plug y Wait for 15 seconds y Put the device back into operation y Open the disinfected water tap and allow the water to run for at least 180 seconds If the fault persists y Consult the HYPRO app for further details y Contact the customer service centre The middle LED flashes yellow for longer than 5 m...

Page 44: ...y Check the hose connections and safety clips Screw cap for the filter chamber incorrectly closed y Check whether the screw cap for the filter chamber is fully closed If the fault persists y Close the angle valve of the cold water pipe y Get in touch with your installer The screw cap for the filter chamber does not release The pressure in the device has not been relieved y Relieve the pressure in ...

Page 45: ...old water pipe to close it y Turn the shut off valve in the CLOSE direction y Open the tap for disinfected water until no further water flows out y Close the disinfected water tap again y Pull out the reducer piece F y Unscrew the T piece K or the connection piece H from the drinking water tap y Unscrew the knurled screw N at the bottom and remove from the wall bracket C y Remove the device y Disa...

Page 46: ...nsure environmentally friendly disposal 9 2 Disposing of used filters The used adsorption material must not be regenerated or reused y Dispose of used filters with residual waste 9 3 Disposing of the device D ATTENTION Danger of environmental damage due to incorrect disposal of the device The device must not be disposed of with household waste y Do not dispose of the device with normal household w...

Page 47: ...e 68 32051 Herford Germany E mail info hytecon com Telephone 49 5221 28400 0 10 2 Privacy policy You can view the privacy policy at www hytecon com 10 3 Patents This product is protected by the following patents U S Patent US 10 377 644 B2 U S Patent US 10 570 030 B2 U S Patent US 2020 0399144 A1 10 4 TÜV certificate 10 5 Spare parts The spare parts can be ordered in the online shop at www hytecon...

Page 48: ... having been carried out before or after the system 10 7 NSF ANSI Compounds certified under NSF ANSI 401 are incidental contaminants that have been detected in drinking water supplies at trace levels These compounds can affect the public perception of drinking water quality This Class B system or component conforms to NSF ANSI 55 for the supplemental bactericidal treatment disinfected public drink...

Page 49: ... water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system as specified in NSF ANSI 42 53 and 401 Substance Influent Challenge Concentration Reduction Requirements Max Permissible Product Water Concentration Reduction NSF ANSI 42 Aesthetic Effects Chlorine Taste and Odor mg L as chlorine 2 0 10 50 97 NSF ANSI 53 Health Effects...

Page 50: ...rsion which we have placed on the market complies with the relevant harmonisation legislation of the European Union 2014 53 EU 2011 65 EU Harmonised standards applied are in particular ETSI EN 300 330 V2 1 1 2017 02 ETSI EN 300 328 V2 1 1 2016 11 ETSI EN 301 489 1 V2 1 1 2017 02 ETSI EN 301 489 3 V1 6 1 2013 08 DIN EN IEC 63000 2019 05 Technical documentation HYTECON AG Brunnhalde 10 CH 6006 Luzer...

Page 51: ...radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Cons...

Page 52: ...05 2021 ...

Reviews: