NOTE:
Communication error codes may appear during
this process. This is a normal part of the calibration proc-
ess.
6.
The lift truck will start up in calibration mode and the
tiller handle will begin to move on its own power dur-
ing the calibration cycle.
7.
Wait at least 5 seconds after the calibration cycle has
ended (the tiller has stopped moving) and remove the
jumper wire.
8.
Wait at least 5 seconds after the jumper wire is re-
moved and cycle the key switch to
OFF
and then back
to
ON
.
9.
If no power steering error appears, the power steering
system was calibrated successfully.
10.
Check the lift truck for proper operation. Reinstall the
drive unit compartment cover and return to the lift
truck to service.
A.
BRAKE ON
B.
REGEN BRAKING
C.
BRAKE OFF
Figure 4. Brake Activation
Control Handle
CONTROL HANDLE HEAD
The control handle head is primarily an electronic compo-
nent and is discussed in the electrical section. For instruc-
tions on how to remove, install, or repair the control handle
head, refer to the section
Electrical System
2200SRM1640.
CONTROL HANDLE
The following procedures describe the removal and disas-
sembly of parts of the control handle and dash assembly for
repairs. The control handle and dash assembly may also be
removed as a single unit with no further disassembly. This
is useful when the control handle and dash assembly must
be removed to access other components of the lift truck.
For instruction on how to remove the control handle and
dash assembly as a complete unit, see Steer Support As-
sembly in this section.
Standard Steering
WARNING
The gas springs used on the control handle are
installed under tension and can release with
enough force to cause personal injury or property
damage.
WARNING
The capacitor in the controller can hold an electri-
cal charge after the battery is disconnected. To
prevent electrical shock and personal injury, dis-
charge the capacitor before inspecting or repair-
ing any component in the drive unit compartment.
See Special Precautions in this section. Wear
safety glasses. Make certain the battery has been
disconnected.
Refer to Figure 5 for the following instructions.
Control Handle
1600 SRM 1637