Table 2. Fault Codes
Code
Description
To troubleshoot symptoms that do not generate a fault code, refer to Non-Status
Code Errors, in this section.
Check Battery
High or low DC link voltage.
High Temp
Thermal cut-back due to high motor temperature or high power bridge
temperature.
Overheat
Overheated motor or power bridge.
Overload
Pump in relief.
Release Coast
Coast system engage switch tied down at key ON.
Release Horn
Horn switch tied down at key ON.
Release Lift/Lower
Lift or lower switch tied down at key ON.
Release Rabbit
High speed switch tied down at key ON or activated before throttle.
Reset Handle
Tiller was pulled down at key on or throttle was requested before the steer arm
was moved into active region, or open load at regen switch or tiller enable switch.
Stalled
Loss of signal from encoder or encoder is disconnected.
Stalled
Open load at encoder or brake coil.
9024
Controller failure of the traction motor power circuit.
9088
Pump motor shorted.
9089
Pump motor open.
9090
Pump at relief.
9091
Controller failure of the pump motor power circuit.
12808
Error in steer handle card speed/direction sensor.
12813
Steer handle sensor is out of limits.
12814
Steer handle card signaled that a belly switch error has occurred.
12816
Controller internal voltage over 36 volts.
12819
Incorrect voltage battery connected.
12832
Controller internal voltage less than 16 volts.
12835
Incorrect voltage battery connected.
13316
Pump proportional valve (coil) open load or over current.
13317
Horn open load.
13384
Main contactor bridge (coil) open.
16912
Controller power section is over temperature.
16944
Controller is in thermal cutback - high controller temperature.
16945
Controller internal temperature sensor failure.
17168
Traction motor is over temperature.
17169
Controller is in thermal cutback - high traction motor temperature.