background image

2200 SRM 1286

Troubleshooting

Table 2. Fault Codes

Code

Description

To troubleshoot symptoms that do not generate a fault code, refer to Non-Status
Code Errors, in this section.

Check Battery

High or low DC link voltage.

High Temp

Thermal cut-back due to high motor temperature or high power bridge
temperature.

Overheat

Overheated motor or power bridge.

Overload

Pump in relief.

Release Coast

Coast system engage switch tied down at key ON.

Release Horn

Horn switch tied down at key ON.

Release Lift/Lower

Lift or lower switch tied down at key ON.

Release Rabbit

High speed switch tied down at key ON or activated before throttle.

Reset Handle

Tiller was pulled down at key on or throttle was requested before the steer arm
was moved into active region, or open load at regen switch or tiller enable switch.

Stalled

Loss of signal from encoder or encoder is disconnected.

Stalled

Open load at encoder or brake coil.

9024

Controller failure of the traction motor power circuit.

9088

Pump motor shorted.

9089

Pump motor open.

9090

Pump at relief.

9091

Controller failure of the pump motor power circuit.

12808

Error in steer handle card speed/direction sensor.

12813

Steer handle sensor is out of limits.

12814

Steer handle card signaled that a belly switch error has occurred.

12816

Controller internal voltage over 36 volts.

12819

Incorrect voltage battery connected.

12832

Controller internal voltage less than 16 volts.

12835

Incorrect voltage battery connected.

13316

Pump proportional valve (coil) open load or over current.

13317

Horn open load.

13384

Main contactor bridge (coil) open.

16912

Controller power section is over temperature.

16944

Controller is in thermal cutback - high controller temperature.

16945

Controller internal temperature sensor failure.

17168

Traction motor is over temperature.

17169

Controller is in thermal cutback - high traction motor temperature.

9

Summary of Contents for B233

Page 1: ...Hyster B233 B80ZAC Forklift...

Page 2: ...AC MOTOR CONTROLLER B60ZAC B230 B80ZAC B233 B60ZHD A262 B80ZHD A257 PART NO 1640805 2200 SRM 1286...

Page 3: ...cifications of the original equipment manufacturer Make sure all nuts bolts snap rings and other fastening devices are removed before using force to remove parts Always fasten a DO NOT OPERATE tag to...

Page 4: ...k Deceleration 6 Battery Full Voltage 6 Lift Interrupt 6 Troubleshooting 6 General 6 Non Status Code Errors 7 Powered Black Screen 7 Tiller Oscillation and Bias EPAS Option 8 Status Codes 8 Electrical...

Page 5: ...ore information Please click here Then get the complete manual NOTE If there is no response to click on the link above please download the PDF document first and then click on it Have any questions pl...

Page 6: ...Table of Contents AC Motor Controller TABLE OF CONTENTS Continued This section is for the following models B60ZAC B230 B80ZAC B233 B60ZHD A262 B80ZHD A257 ii...

Page 7: ...nts and connecting or disconnecting a handset or PC CAUTION To avoid controller damage always disconnect the battery Discharge the capacitor and never put power to the controller with any power wire d...

Page 8: ...ering motor The controller uses CANbus communication to interact with the dash display and the control handle See Figure 2 1 GRAB RAIL 2 AUXILIARY CONTROL BOX 3 DASH DISPLAY 4 POWER FUSE 5 PC CONNECTO...

Page 9: ...he cover from the controller will void the war ranty Service PC Connection The lift truck is equipped with a connection point to connect a laptop computer with ETACC software in stalled This connectio...

Page 10: ...v 3 3 1 10 PS Rev Trav 3 3 1 10 PS Max Assist 5 5 1 10 NOTE Certain lift truck models are not capable of operating at the Max range allowed by the Dash Display If a parameter value higher than the tru...

Page 11: ...the minimum rate of acceleration Maximum Acceleration This parameter sets the maximum acceleration rate of the lift truck when the truck is traveling at max imum throttle Increasing the setting increa...

Page 12: ...uity from the front pin end of the plug Standard probes are too large to be inserted into the center of the female pins sockets of the special sealed plugs and can expand the pins Expanded pins will n...

Page 13: ...stic tool Yes Connect ETACC to the forklift PC Ser vice Tool connector following the instructions in the section Troubleshooting and Adjust ments Using the AC Controls Program ETACC 2200 SRM 1058 ETAC...

Page 14: ...nd cause an increase of the backlash in the system which is a root caused of the chattering Lower assist level as necessary After ensuring all the aforementioned requirements are met the system must b...

Page 15: ...m encoder or encoder is disconnected Stalled Open load at encoder or brake coil 9024 Controller failure of the traction motor power circuit 9088 Pump motor shorted 9089 Pump motor open 9090 Pump at re...

Page 16: ...1568 Main contactor circuit is open 21569 Main contactor circuit is shorted to B 21570 Main contactor circuit is open 21571 Main contactor circuit is shorted to B 21588 Internal failure of the power s...

Page 17: ...ring controller 33072 Controller not responding to Power Steer 33073 Power Steer not responding to Controller 33554 Power Steer motor stalled 36864 Power Steering security line set to LOW 65280 Contro...

Page 18: ...ltage battery 3 Check to have battery fully charged approximately 25 5V 1V 4 Condition can be caused by normal operation of the lift truck with a discharged battery Check battery state of charge on th...

Page 19: ...ce Service Technician Functions On Board Dash Display 2200 SRM 1324 3 With the traction motor at room temperature turn the key switch to the OFF position then back to the ON position and operate the l...

Page 20: ...Electrical System 2200 SRM 1451 or Electrical System 2200 SRM 1287 Contactor Coil Check a The resistance should measure approximately 22 ohms 10 Replace the coil 7 Check for shorts with truck frame a...

Page 21: ...sed by shorts in the system allowing current to follow paths that are not intended Sometimes excessive current draw can be caused by mechanical malfunctions such as worn bearings misaligned parts impr...

Page 22: ...r to cool System will recover once the truck is able to achieve a temperature below 125 C 257 F 2 Clear fault log in dash display See the section User Interface Service Technician Functions On Board D...

Page 23: ...not operate Probable Causes and Test Procedures 6 Check for shorts with truck frame a Check resistance between the following points for greater than 1Mohm CANH and truck frame CANL and truck frame B a...

Page 24: ...y caused by shorts in the system allowing current to follow paths that are not intended Sometimes excessive current draw can be caused by mechanical malfunctions such as worn bearings misaligned parts...

Reviews: