816 LA Actuator
INSTALLATION REFERENCE MANUAL
19
13
SETTING MOTOR 2 OPEN/CLOSE LIMITS
1. A
fter setting limits of primary actuator (INSTRUCTION 12), disconnect it from the MOTOR 1 con-
nector and plug the secondary actuator harness into the MOTOR 1 connector.
2. Using the appropriate button(s) on the control board, cycle the gate(s) to the open and close
position. If close and open limits are not acceptable, adjust the limit switch in the 816 actuator as
follows:
• Extended actuator: EXTEND more - Turn the EXTEND limit screw counterclockwise
• Extended actuator: EXTEND less - Turn the EXTEND limit screw clockwise
• Retracted actuator: RETRACT more - Turn the RETRACT limit screw clockwise
• Retracted actuator: RETRACT less - Turn the RETRACT limit screw counterclockwise
3. Once both actuator limits are set, plug the primary actuator into the MOTOR 1 connector, and
plug the secondary actuator into the MOTOR 2 connector on the cotrol board.
NOTE:
Refer to the appropriate control box installation manual for programming and and accessory
wiring connections.
After following instructions in INSTRUCTION 12 for adjusting limits of the MOTOR 1 actuator, follow the
steps below to set limits for the MOTOR 2 actuator.
www.ApolloGateOpeners.com | (800) 878-7829 | [email protected]