816 LA Actuator
INSTALLATION REFERENCE MANUAL
14
5.1 WIRING ACTUATOR TO 936 CONTROL BOARD
I
MAGE 8-2:
PULL-TO-OPEN - SINGLE
IMAGE 8-3:
PULL-TO-OPEN - DUAL
MOTOR 1
MOTOR 2
1. Locate MOTOR 1 and MOTOR 2 connectors on 936 board per IMAGE 8-1.
1. If single gate, wire MOTOR 1 connector per IMAGE 8-2 (PULL-TO-OPEN).
2. If dual gate, wire MOTOR 1 & 2 connectors per IMAGE 8-3 (PULL-TO-OPEN)..
PULL-TO-OPEN (SINGLE GATE)
PULL-TO-OPEN (DUAL GATE)
8
936 CONTROL BOARD WIRING: PULL-TO-OPEN
WHITE
BLUE
GREEN
YELLOW
ORANGE
BLACK
RED
MOTOR 1
WHITE
BLUE
GREEN
YELLOW
ORANGE
BLACK
RED
WHITE
BLUE
GREEN
YELLOW
ORANGE
BLACK
RED
MOTOR 1
MOTOR 2
IMAGE 8-1:
936 MOTOR CONNECTOR LOCATIONS
NOTE:
If a gate moves in opposite
direction from what is expected,
reverse the motor power lead
wiring (red & black wires) for
that motor.
In dual gate systems, the
longer actuator cable is usually
conneted to MOTOR 2.
www.ApolloGateOpeners.com | (800) 878-7829 | [email protected]