![Hypertherm powermax900 Operator'S Manual Download Page 34](http://html1.mh-extra.com/html/hypertherm/powermax900/powermax900_operators-manual_2193782034.webp)
3-7
S
ETUP
Operator Manual
SINGLE-PHASE AND THREE-PHASE POWER CONFIGURATIONS
All Powermax900 power supplies except the 400V CE and 600V power supplies can operate from
either a single-phase or three-phase input. The 400V CE, 230V CE and 600V power supplies operate
only from a three-phase input.
Power cords must meet the specifications described earlier in this section. Follow applicable local or
national wire-color conventions. See also
EMC Compatibility
and
Mains Supply on page i for further
CE compliance recommendations.
Remove the rear panel (Fig. 3-2) and connect the power cable to terminal block TB1 as shown in
the figures below. Connect the ground wire to the stud marked above the terminal block.
Single-Phase
Three-Phase - Non-CE
WARNING
SHOCK HAZARD: Always turn off power, unplug cord from wall and wait 5 minutes before
removing any power supply cover. If power supply is directly connected to a line disconnect
switch, place line disconnect switch to OFF position. In the U.S., use a "lock-out / tag-out"
procedure until the service or maintenance work is complete. In other countries, follow
appropriate national or local safety procedures.
Black
White
Green
TB1
Conductor
Color
Line (U)
Black or Brown
Neutral/Line (V) White or Blue
Ground
Green or Green/Yellow
Figure 3-7
Single-Phase Power
Conductor
Color
L1 (U)
Brown or Black
L2 (V)
Blue or White
L3 (W)
Black or Red
Ground
Green/Yellow or Green
Figure 3-8
Three-Phase Power
Non-CE
Brown
Blue
Black
Green/Yellow
TB1
Summary of Contents for powermax900
Page 1: ......
Page 15: ...SAFETY 1 6 Hypertherm Plasma Systems 8 99 ...
Page 21: ...SÉCURITÉ 1a 6 08 99 HYPERTHERM Systèmes plasma ...
Page 50: ...OPERATION 4 9 Operator Manual Figure 4 8 Dragging the Torch Figure 4 7 Cutting a Circle ...
Page 69: ...Operator Manual 5 14 MAINTENANCE PARTS ...
Page 73: ...APPENDIX B Operator Manual ...