4-2
O
PERATION
Operator Manual
CONTROLS AND INDICATORS
•
Green POWER ON LED
When illuminated, indicates that all control circuits are activated, the torch safety interlock is
satisfied and the system is ready for operation.
•
Green LINE VOLTAGE LED
When illuminated green, indicates that the AC line voltage is within proper operating limits. If dis-
abled, (white) or if illuminated or blinking any other color, see
Basic Troubleshooting in
Section 5
.
•
Yellow TEMP LED
When illuminated, indicates that the power supply temperature has exceeded operating limits.
•
Green GAS PRESSURE LED
When illuminated, indicates that the gas pressure is within operating limits.
•
GAS TEST Switch
When pushed in, allows the operator to view and adjust the pressure setting.
•
AMPS Output Adjustment Knob
Adjusts output current between 20 and 55 amps.
•
Pressure Regulator
Regulates input gas pressure to power supply.
•
Pressure Gauge
Indicates gas pressure at power supply.
•
ON (I)/OFF (0) Power Switch
Activates the power supply and its control circuits.
GAS
PRESSURE
Figure 4-1 Powermax900 Controls and Indicators
Pressure Gauge
Pressure Regulator
AMPS
ON (I)/OFF (0) Power Switch
POWER
ON
LINE
VOLTAGE
TEMP
GAS
TEST
9-99