SETUP
0
3-6
powermax
1000
Operator Manual
Grounding
To ensure personal safety and proper operation, and to reduce electromagnetic interference (EMI), the
Powermax1000 must be properly grounded through the power cord according to national or local
electrical codes. Three-phase service must be of the 4-wire type with a green or green/yellow wire for
protective earth ground and must comply with national or local electrical requirements. Single-phase
service must be of the 3-wire type with a green or green/yellow wire for protective earth ground and must
comply with national or local electrical requirements. Refer to Grounding, in the Safety section.
Extension Cords
Use a cord that is certified by national or local codes. The cord should be installed by a licensed
electrician. Refer to the length requirements listed below.
Recommended Extension Cord Gauge Size AWG (mm
2
)
< 10 ft
10-25 ft
25-50 ft
50-100 ft
100-150 ft
< 3 m
3 – 7.5 m
7.5 – 15 m
15 – 30 m
30 – 45 m
Standard Model
Input-
Voltage
Phase
AWG
mm
2
AWG
mm
2
AWG
mm
2
AWG
mm
2
AWG
mm
2
200-208 VAC
1
8
(10)
8
(10)
8
(10)
6
(16)
4
(25)
230 VAC
1
8
(10)
8
(10)
8
(10)
6
(16)
4
(25)
480 VAC
1
12
(4)
12
(4)
12
(4)
10
(6)
10
(6)
200-208 VAC
3
10
(6)
10
(6)
10
(6)
8
(10)
8
(10)
230 VAC
3
10
(6)
10
(6)
10
(6)
8
(10)
8
(10)
400 VAC
3
12
(4)
12
(4)
12
(4)
12
(4)
10
(6)
480 VAC
3
12
(4)
12
(4)
12
(4)
12
(4)
10
(6)
600 VAC
3
12
(4)
12
(4)
12
(4)
12
(4)
12
(4)
CE Model
Phase
mm
2
mm
2
mm
2
mm
2
mm
2
230 VAC
3
(4)
(4)
(6)
(6)
(10)
400 VAC
3
(4)
(4)
(4)
(6)
(6)