OPERATION
0
4-6
powermax
1000
Operator Manual
Adjust Gas Pressure and Current Setting
20
60
AMPS
30
40
50
Set current knob to gas test.
Pull regulator knob to unlock.
6.0
BAR
5.0
4.0
PSI
80
70
50
60
20
60
AMPS
30
40
50
Set pressure:
Cutting
70–75 psig (4.8–5.2 bar)
Gouging
50–60 psig (3.4–4.1 bar)
Push regulator knob to lock.
Turn current knob away from gas test to stop