SETUP
0
3-4
powermax
1000
Operator Manual
Standard Model
Input Voltage
200-208
230-240
480
200-208
230-240
400
480
600
Input Current at 8.4kw Output
50
44
22
30
26
15
12
11
Input Current during Arc
Stretch
75
75
38
45
45
26
20
19
CE Model
Input Voltage
230
400
Input Current at 8.4kw Output
26
15
Input Current during Arc
Stretch
45
26
Single Phase
Three Phase
Three Phase
Power Connection
The Powermax1000 is a universal power supply that can configure itself to operate with AC voltages from
200 to 600 (230-400 3PH for CE model). Use a line disconnect switch for each power supply so that the
operator can turn off the power supply quickly in an emergency. Locate the switch so it is easily accessi-
ble to the operator. The interrupt level of the switch must be equal to or exceed the continuous rating of
the fuses. Use slow-blow fuses rated per local and national electrical codes.
Three-Phase Power Cord – Plug Installation
The Powermax1000 power supplies are shipped with an 8 AWG 4-wire power cord on standard models.
A 4 mm
2
,
4-wire HAR power cord is provided on CE models. To operate the Powermax1000, use a plug
that meets national or local electrical codes. The plug must be connected to the power cord by a licensed
electrician.