InstallatIon
HPR400XD Auto Gas –
806160
3-31
Notes to cNc interface cable run list
Note 1. I
nputs are optically isolated. They require 24 VDC at 7.3 mA, or dry-contact closure.
The external relay’s life
may be improved by adding a metallized-polyester capacitor (0.022µF 100V or higher) in parallel with the relay
contacts
Note 2.
Outputs are optically isolated, open collector, transistors. The maximum rating is 24 VDC at 10 mA.
Note 3. Machine motion is selectable and is used for configurations with multiple plasma systems.
Note 4.*
CNC +24 VDC provides 24 VDC at 200 mA maximum. A jumper is required on J301 to use 24 V power.
* See example 1 on page 3-33
caution:
the cNc cable must be constructed using cable with 360 degree shielding and
metal housing connectors at each end. the shielding must be terminated to the
metal housings at each end to ensure proper grounding and to provide the best
shielding.
Summary of Contents for HyPerformance Plasma HPR400
Page 1: ...HyPerformance Plasma HPR400XD Auto gas Instruction manual 806160 Revision 4 ...
Page 26: ...Specifications 2 2 HPR400XD Auto Gas 806160 ...
Page 48: ...Installation 3 10 HPR400XD Auto Gas 806160 ...
Page 53: ...Installation HPR400XD Auto Gas 806160 3 15 Horizontal RHF mounting Vertical RHF mounting ...
Page 57: ...Installation HPR400XD Auto Gas 806160 3 19 This page is blank intentionally ...
Page 65: ...Installation HPR400XD Auto Gas 806160 3 27 7 8 8 7 ...
Page 100: ...Installation 3 62 HPR400XD Auto Gas 806160 ...
Page 107: ...Operation HPR400XD Auto Gas 806160 4 7 Diagnostic screen ...
Page 108: ...Operation 4 8 HPR400XD Auto Gas 806160 Test screen ...
Page 109: ...Operation HPR400XD Auto Gas 806160 4 9 Cut chart screen ...
Page 197: ...Operation HPR400XD Auto Gas 806160 4 97 ...
Page 287: ...7 4 HPR400XD Auto Gas 806160 Discrete output functionality ...
Page 347: ...Appendix B CNC Interface Protocol b 28 HPR400XD Auto Gas 806160 ...
Page 355: ...4 HPR400XD Auto Gas 806160 ...