InstallatIon
HPR400XD Auto Gas –
806160
3-57
gas requirements
The customer must furnish all gases and gas-supply regulators for the system. Use a high-quality, 2-stage pressure
regulator located within 3 m (10 ft) of the selection console. See
gas regulators
in this section for recommendations.
See the
Specification
section for gas and flow specifications. See
Supply gas hoses
at the end of this section for
recommendations.
Setting the supply regulators
1. Turn OFF the power to the system. Set all gas
regulator pressures to 8 bar (115 psi).
2. Turn ON the power to the system using the remote
ON/OFF switch or the CNC.
3. Set to Test Preflow.
4. While gas is flowing adjust the supply regulator for the
shield gas to 8 bar (115 psi).
5. Turn OFF Test Preflow.
6. Set system to Test Cutflow.
7. While gas is flowing adjust the supply regulator for the
plasma gas to 8 bar (115 psi).
8. Turn OFF Test Cutflow.
caution:
gas supply pressures not within the specifications in Section 2 can cause
poor cut quality, poor consumable life and operational problems.
If the purity level of the gas is too low or if there are leaks in the supply
hoses or connections,
• Cut speeds can decrease
• Cut quality can deteriorate
• Cutting thickness capability can decrease
• Parts life can shorten
Summary of Contents for HyPerformance Plasma HPR400
Page 1: ...HyPerformance Plasma HPR400XD Auto gas Instruction manual 806160 Revision 4 ...
Page 26: ...Specifications 2 2 HPR400XD Auto Gas 806160 ...
Page 48: ...Installation 3 10 HPR400XD Auto Gas 806160 ...
Page 53: ...Installation HPR400XD Auto Gas 806160 3 15 Horizontal RHF mounting Vertical RHF mounting ...
Page 57: ...Installation HPR400XD Auto Gas 806160 3 19 This page is blank intentionally ...
Page 65: ...Installation HPR400XD Auto Gas 806160 3 27 7 8 8 7 ...
Page 100: ...Installation 3 62 HPR400XD Auto Gas 806160 ...
Page 107: ...Operation HPR400XD Auto Gas 806160 4 7 Diagnostic screen ...
Page 108: ...Operation 4 8 HPR400XD Auto Gas 806160 Test screen ...
Page 109: ...Operation HPR400XD Auto Gas 806160 4 9 Cut chart screen ...
Page 197: ...Operation HPR400XD Auto Gas 806160 4 97 ...
Page 287: ...7 4 HPR400XD Auto Gas 806160 Discrete output functionality ...
Page 347: ...Appendix B CNC Interface Protocol b 28 HPR400XD Auto Gas 806160 ...
Page 355: ...4 HPR400XD Auto Gas 806160 ...