Appendix B – CnC interfACe protoCol
HPR400XD Auto Gas –
806160
b-17
ID
command
System
Description
122 READ_GAS_SWITCH
Manual gas system This command will return data that shows the actual position of
the rotary switches used to set the inlet gas type.
The difference between this command and 098 is that this
command returns the values set by the position of the switch.
The 098 command returns values that the software decides are
acceptable gas combinations. For example, H35 plasma and O
2
shield is not acceptable and is overridden by the software to be
H35 plasma and N
2
shield regardless of the position of the shield
gas knob. In this case, the 098 command would return H35 N
2
.
This command will return H35 O
2
.
Data:
None
Return value:
Plasma gas type code (See table VI),
Shield gas type code (See table VI),
space-delimited
Sample:
>12295<
>1220001 00063C<
124 INDEX_MOTORVALVES
Auto gas system
Move the motor valve by a fixed number of ADC counts
Data:
Motor Valve number (1 or 2)
Open/Clos (0 = Close, 1 = Open)
Multiplier (move by x10 counts, 3 = move 30 counts)
Return value:
1 = accepted
Sample:
Open Motor valve 1 by 30 counts
>1241 1 36C<
>1241C8<
125 GET_TIMER_COUNTER
Manual gas system
Auto gas system
Read Timer/Counter data from the power supply
Data:
None
Return value:
Arc-on time (seconds)
System on time (minutes)
Total starts (# of arc transfers)
Total starting errors (failed to transfer)
Total ramp-down errors (failed to ramp-down current)
Write counter (# of writes to the present memory block – for
diagnostics only)
Memory block (current memory location for timer counter data –
for diagnostics only)
All fields are a fixed width of 7 numbers followed by a space.
Sample:
>12598<
>1250000000 0000000 0000000 0000000 0000000 0000000
0000000 58<
command table (12 of 14)
Summary of Contents for HyPerformance Plasma HPR400
Page 1: ...HyPerformance Plasma HPR400XD Auto gas Instruction manual 806160 Revision 4 ...
Page 26: ...Specifications 2 2 HPR400XD Auto Gas 806160 ...
Page 48: ...Installation 3 10 HPR400XD Auto Gas 806160 ...
Page 53: ...Installation HPR400XD Auto Gas 806160 3 15 Horizontal RHF mounting Vertical RHF mounting ...
Page 57: ...Installation HPR400XD Auto Gas 806160 3 19 This page is blank intentionally ...
Page 65: ...Installation HPR400XD Auto Gas 806160 3 27 7 8 8 7 ...
Page 100: ...Installation 3 62 HPR400XD Auto Gas 806160 ...
Page 107: ...Operation HPR400XD Auto Gas 806160 4 7 Diagnostic screen ...
Page 108: ...Operation 4 8 HPR400XD Auto Gas 806160 Test screen ...
Page 109: ...Operation HPR400XD Auto Gas 806160 4 9 Cut chart screen ...
Page 197: ...Operation HPR400XD Auto Gas 806160 4 97 ...
Page 287: ...7 4 HPR400XD Auto Gas 806160 Discrete output functionality ...
Page 347: ...Appendix B CNC Interface Protocol b 28 HPR400XD Auto Gas 806160 ...
Page 355: ...4 HPR400XD Auto Gas 806160 ...