OperatiOn
4-40
HPR400XD Auto Gas –
806160
Mild steel Fine F
eature
c
utting
30 A to 260 A
English
Material thickness
c
urrent
Select Gases
Set Preflow
Set Cutflow
Arc
Voltage
Torch- to-Work Distance
Cutting Speed
Initial Pirece
Height
Pierce Delay Time
in
Amps
Plasma
gas
Shield gas
Plasma
gas
Shield gas
Plasma
gas
Shield gas
Volts
in
ipm
in
Factor
%
Seconds
0.135
30
O
2
O
2
78
75
94
7
123
0.06
40
0.11
180
0.5
3/16
128
30
0.7
1/4
50
O
2
O
2
70
30
81
14
125
0.08
35
0.16
200
0.5
5/16
80*
O
2
Air
48
23
78
25
119
0.06
90
0.16
267
0.4
3/8
121
70
0.5
3/8
130
O
2
Air
32
32
84
27
128
0.09
98
0.24
267
0.3
1/2
25
132
0.10
70
0.26
260
0.5
5/8
200
O
2
Air
23
42
74
14
130
0.08
70
0.32
400
0.6
3/4
15
0.09
356
0.8
3/4
260
O
2
Air
22
49
80
47
158
0.09
80
0.35
389
0.6
7/8
49
166
0.14
75
250
0.7
1
84
171
65
0.8
Note:
*T
he pierce complete signal must be turned off for the 8
0 A processes.
Summary of Contents for HyPerformance Plasma HPR400
Page 1: ...HyPerformance Plasma HPR400XD Auto gas Instruction manual 806160 Revision 4 ...
Page 26: ...Specifications 2 2 HPR400XD Auto Gas 806160 ...
Page 48: ...Installation 3 10 HPR400XD Auto Gas 806160 ...
Page 53: ...Installation HPR400XD Auto Gas 806160 3 15 Horizontal RHF mounting Vertical RHF mounting ...
Page 57: ...Installation HPR400XD Auto Gas 806160 3 19 This page is blank intentionally ...
Page 65: ...Installation HPR400XD Auto Gas 806160 3 27 7 8 8 7 ...
Page 100: ...Installation 3 62 HPR400XD Auto Gas 806160 ...
Page 107: ...Operation HPR400XD Auto Gas 806160 4 7 Diagnostic screen ...
Page 108: ...Operation 4 8 HPR400XD Auto Gas 806160 Test screen ...
Page 109: ...Operation HPR400XD Auto Gas 806160 4 9 Cut chart screen ...
Page 197: ...Operation HPR400XD Auto Gas 806160 4 97 ...
Page 287: ...7 4 HPR400XD Auto Gas 806160 Discrete output functionality ...
Page 347: ...Appendix B CNC Interface Protocol b 28 HPR400XD Auto Gas 806160 ...
Page 355: ...4 HPR400XD Auto Gas 806160 ...